Power supply unit - EM-CPS-PS/3AC/24DC/5 - 1064922

Primary-switched power supply unit, TRIO POWER, Snap-on connection, Cross Power System - installation, input: 3-phase, output: 24 V DC / 5 A

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



 

Block diagram

Back to top

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Back to top

Dimensions

Width 36 mm
Height 160 mm
Depth 159 mm
Back to top

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Installation height ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Back to top

Input data

Nominal input voltage range 3x 400 V AC ... 500 V AC
2x 400 V AC ... 500 V AC
Input voltage range 3x 400 V AC ... 500 V AC -20 % ....+15 %
2x 400 V AC ... 500 V AC -10 % ... +15 %
AC frequency range 50 Hz ... 60 Hz
Discharge current to PE < 0.25 mA
Current consumption 3x 0.4 A (400 V AC)
3x 0.3 A (500 V AC)
2x 0.6 A (400 V AC)
2x 0.5 A (500 V AC)
Nominal power consumption 243.6 VA
Inrush current ≤ 22 A (typical)
Mains buffering time typ. 20 ms (400 V AC)
typ. 20 ms (500 V AC)
Input fuse 3.15 A (internal (device protection), slow-blow)
Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi) 0.55
Type of protection Transient surge protection
Protective circuit/component Varistor
Back to top

Output data

Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN) 5 A
Dynamic Boost (IDyn.Boost) 7.5 A (5 s)
Derating > 60 °C ... 70 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity
Connection in series yes
Protection against overvoltage at the output (OVP) ≤ 30 V DC
Control deviation < 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple ≤ 20 mVPP
Output power 120 W
Typical response time < 1 s
Maximum power dissipation in no-load condition < 1 W (400 V AC)
Power loss nominal load max. < 12 W (480 V AC)
Back to top

General

Net weight 0.7 kg
Efficiency typ. 91 % (400 V AC)
Insulation voltage input/output 3 kV AC (type test)
1.5 kV AC (routine test)
Protection class II (in closed control cabinet)
Degree of protection IP20
MTBF (IEC 61709, SN 29500) > 2300000 h (25 °C)
> 1300000 h (40 °C)
> 620000 h (60 °C)
Assembly instructions Cross Power System
Back to top

Connection data, input

Connection method Snap-on connection
Back to top

Connection data, output

Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 10 mm
Back to top

Connection data for signaling

Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm
Back to top

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise emission EN 55011 (EN 55022)
Noise immunity Immunity according to EN 61000-6-2 (industrial)
Standards/regulations EN 61000-4-2
Contact discharge 4 kV (Test Level 2)
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 1.4 GHz ... 2 GHz
Test field strength 3 V/m (Test Level 2)
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-6-4
EN 61000-6-2
Conducted noise emission EN 55016 EN 61000-6-4 (Class A)
Standards/regulations EN 61000-4-11
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safety IEC 61010-1 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 61010 (SELV) / (PELV)
Standard - Safe isolation DIN VDE 0100-410
Standard – Limitation of mains harmonic currents EN 61000-3-2
UL approvals UL Listed UL 61010-2-201
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) 10 ... 150 Hz, amplitude ±0.35 mm, 5g, 90 min. (in accordance with IEC 60068-2-6)
2 Hz ... 15 Hz, amplitude ±1 mm, > 15 Hz, 0.7g (in accordance with DNV GL Class A)
Overvoltage category (EN 61010-1) II
Back to top

Classifications

eCl@ss

eCl@ss 6.0 27049000
eCl@ss 7.0 27049002
eCl@ss 8.0 27049002
eCl@ss 9.0 27040701
Back to top

ETIM

ETIM 5.0 EC002540
ETIM 6.0 EC002540
ETIM 7.0 EC002540
Back to top

PHOENIX CONTACT Ltd

Unit 15C, 906-930 Great South Road, Penrose
Auckland 1061
New Zealand

Phone: 0508 474 636
Toll Free (Local)
09 950 8495
  • Create PDF
  • Recommend
  • Feedback

This website uses cookies, by continuing to browse, you agree to our cookie policy. Read our privacy policy for more information.

Close