Monitoring relay - EMD-SL-LL-110 - 2901137

Monitoring relay for level monitoring of conductive fluids, minimum monitoring, maximum monitoring, 110 V AC supply voltage, 2 PDTs

Price:

Overview

Technical data

Approvals

Downloads

Drawings



Block diagram  

Block diagram

Back to top

Dimensions

Width 22.5 mm
Height 90 mm
Depth 113 mm
Back to top

Ambient conditions

Ambient temperature (operation) -25 °C ... 55 °C
-25 °C ... 40 °C (corresponds to UL 508)
Ambient temperature (storage/transport) -25 °C ... 70 °C
Permissible humidity (operation) 15 % ... 85 %
Degree of protection IP40 (Housing)
IP20 (Connection terminal blocks)
Noise immunity EN 61000-6-2
Back to top

Input data

Function Pumping up (minimum monitoring), pumping down (maximum monitoring)
Recovery time 500 ms
Back to top

Contact side

Contact type 2 floating PDT contacts
Maximum switching voltage 250 V AC (in acc. with IEC 60664-1)
Interrupting rating (ohmic load) max. 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)
1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)
Output fuse 5 A (fast-blow)
Back to top

Power supply

Supply voltage 110 V AC -10 % ... +15 % AC
Back to top

General

Mechanical service life approx. 2x 107 cycles
Operating mode 100% operating factor
Mounting position any
Assembly instructions on standard DIN rail NS 35 in accordance with EN 60715
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Housing insulation material Polyamide PA, self-extinguishing
Color green
Back to top

Connection data

Connection method Screw connection
Stripping length 8 mm
Conductor cross section solid 0.5 mm² ... 2.5 mm²
Conductor cross section flexible 0.25 mm² ... 2.5 mm²
Conductor cross section AWG 20 ... 14
Tightening torque 1 Nm
Back to top

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Noise emission EN 61000-6-3
Noise immunity EN 61000-6-2
Standards/regulations EN 50178
Rated insulation voltage 300 V
Insulation Basic insulation
Pollution degree 2
Overvoltage category III
Low Voltage Directive Conformance with LV directive 2006/95/EC
Back to top

Environmental Product Compliance

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 27371813
eCl@ss 11.0 27371813
eCl@ss 4.0 27210100
eCl@ss 4.1 27210100
eCl@ss 5.0 27371800
eCl@ss 5.1 27371800
eCl@ss 6.0 27371800
eCl@ss 7.0 27371802
eCl@ss 8.0 27371802
eCl@ss 9.0 27371813
Back to top

ETIM

ETIM 3.0 EC001440
ETIM 4.0 EC001440
ETIM 5.0 EC001447
ETIM 6.0 EC001440
ETIM 7.0 EC001440
Back to top

UNSPSC

UNSPSC 6.01 30211916
UNSPSC 7.0901 39121535
UNSPSC 11 39121535
UNSPSC 12.01 39121535
UNSPSC 13.2 41113637
UNSPSC 18.0 41113637
UNSPSC 19.0 41113637
UNSPSC 20.0 41113637
UNSPSC 21.0 41113637
Back to top

PHOENIX CONTACT Ltd

Unit 15C, 906-930 Great South Road, Penrose
Auckland 1061
New Zealand

Phone: 0508 474 636
Toll Free (Local)
09 950 8495
  • Create PDF
  • Recommend
  • Feedback