General data

Number of positions 9
Alternative short product description Installation remote bus cable
Back to top

Cable

Signal type/category INTERBUS
Cable structure 3 x 2 x 0.22 mm² + 3 x 1 mm²
Conductor cross section 3x 2x 0.22 mm² (Data)
3x 1 mm² (Supply)
Conductor structure signal line 7x 0.20 mm
Conductor structure, voltage supply 14x 0.30 mm
Core diameter including insulation 1 mm (Data)
1.7 mm (Supply)
Wire colors green-yellow, white-brown, gray-pink, red, blue, green/yellow
Twisted pairs 2 cores to the pair
Overall twist 3 pairs and 3 wires to form the core
Shielding Tinned copper braided shield
External sheath, color black RAL 9005
Inner sheath thickness 0.9 mm
External cable diameter D 9.7 mm ±0,3 mm
Minimum bending radius, fixed installation 7.5 x D
Minimum bending radius, flexible installation 15 x D
Outer sheath, material PVC
Material, inner sheath PVC
Material conductor insulation PE
Conductor material Bare Cu litz wires
Insulation resistance ≥ 5 GΩ*km (Data)
≥ 5 GΩ*km (Supply)
Loop resistance ≤ 186.00 Ω/km (Data)
≤ 19.50 Ω/km (Supply)
Cable capacity ≤ 60 nF/km (At 800 Hz)
Wave impedance 110 Ω ±20 Ω (at 64 kHz)
95 Ω ±15 Ω (at >1 MHz)
Near end crosstalk attenuation (NEXT) ≥ 61 dB (at 772 kHz)
≥ 59 dB (with 1 MHz)
≥ 55 dB (at 2 МHz)
≥ 50 dB (at 4 МHz)
≥ 46 dB (at 8 МHz)
≥ 44 dB (at 10 MHz)
≥ 41 dB (at 16 MHz)
≥ 40 dB (at 20 МHz)
Attenuation ≤ 10 dB/km (at 256 kHz)
≤ 25 dB/km (at 772 kHz)
≤ 28 dB/km (with 1 MHz)
≤ 69 dB/km (at 4 МHz)
≤ 12 dB/km (at 10 MHz)
≤ 15.5 dB/km (at 16 MHz)
≤ 17.2 dB/km (at 20 МHz)
Signal speed 0.66 c
Coupling resistance < 250.00 mΩ/m (at 30 MHz)
Nominal voltage, cable 250 V (Peak value, not for high-power applications)
450 V (Supply)
Test voltage Core/Core 1500 Vrms
Test voltage Core/Shield 1000 Vrms
Flame resistance according to VDE 0472, Part 804, test type B
according to IEC 60332-1
Ambient temperature (operation) -30 °C ... 70 °C (cable, fixed installation)
-5 °C ... 70 °C (cable, flexible installation)
Back to top

Environmental Product Compliance

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 4.0 24010400
eCl@ss 4.1 24010400
eCl@ss 5.0 19030300
eCl@ss 5.1 19030300
eCl@ss 6.0 27061800
eCl@ss 7.0 27061801
eCl@ss 8.0 27061801
eCl@ss 9.0 27061801
Back to top

ETIM

ETIM 2.0 EC000304
ETIM 3.0 EC000830
ETIM 4.0 EC000830
ETIM 5.0 EC000830
ETIM 6.0 EC000830
ETIM 7.0 EC003249
Back to top

UNSPSC

UNSPSC 6.01 43172015
UNSPSC 7.0901 43201404
UNSPSC 11 39121311
UNSPSC 12.01 39121311
UNSPSC 13.2 26121604
Back to top

PHOENIX CONTACT Ltd

Unit 15C, 906-930 Great South Road, Penrose
Auckland 1061
New Zealand

Phone: 0508 474 636
Toll Free (Local)
09 950 8495
  • Create PDF
  • Recommend
  • Feedback

This website uses cookies, by continuing to browse, you agree to our cookie policy. Read our privacy policy for more information.

Close