Patch panels - PP-RJ-IDC-F - 2703023

Patch panel, RJ45 socket on IDC terminal blocks, 10/100/1000 Mbps, DIN rail mounting, IP20, shield contacting with strain relief, shield current monitoring, surge protection

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Dimensional drawing  

Dimensional drawing

Circuit diagram  

Circuit diagram



Schematic diagram  

Schematic diagram
Front view

Schematic diagram  

Schematic diagram
Mounting on a DIN rail



Schematic diagram  

Schematic diagram
Removal

Schematic diagram  

Schematic diagram
Open shield contact spring



Schematic diagram  

Schematic diagram
Inserting the cable

Schematic diagram  

Schematic diagram
Close shield contact spring



Schematic diagram  

Schematic diagram
Shield current monitoring

Schematic diagram  

Schematic diagram
Stripping length



Back to top

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Back to top

Dimensions

Dimensional drawing
Width 23.8 mm
Height 101.3 mm
Depth 86 mm
Back to top

Ambient conditions

Ambient temperature (operation) -40 °C ... 75 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Altitude 5000 m (For restrictions see manufacturer's declaration)
2000 m (ATEX approval)
Degree of protection IP20 (Manufacturer's declaration)
Back to top

General

Electrical isolation FE // Ethernet
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Net weight 124.2 g
Housing material Plastic
Color gray
MTTF 3281 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
1245 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
472 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
Degree of pollution 2
Overvoltage category II
Conformance CE-compliant
ATEX  II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
Class I, Div. 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Back to top

Power supply

Supply voltage range 36 V DC ... 52 V DC 10 % (via PoE)
42 V DC ... 57 V DC (With UL approval)
Back to top

Serial interface

Interface 1 Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u
Connection method IDC connection
Transmission length 100 m (including patch cables)
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 0.34 mm²
Conductor cross section flexible min. 0.14 mm²
Conductor cross section flexible max. 0.34 mm²
Conductor cross section AWG min. 26
Conductor cross section AWG max. 22
Wire diameter incl. insulation 1.6 mm (Terminal block is tested with PVC insulation - other insulation materials available on request)
Pin assignment 1:1
Serial transmission speed 10/100/1000 Mbps
Maximum output current 725 mA (PoE)
Current carrying capacity ≤ 1.5 A (≤ 60 W (PoE+))
Maximum output power 60 W
Interface 2 Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u
Connection method RJ45 CAT5e
Back to top

Function

Designation Shield current monitoring
Switch-on threshold ≥ 30 mA
Local diagnostics Yellow LED
Precision ± 5 %
Response time 3 s
Continuous shield current ≤ 1.5 A
Power consumption 270 mW (Shield current monitoring)
Impedance ≤ 1 Ω
Voltage ≤ 10 V
Back to top

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result 10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g
Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result 30g for 11 ms, three shocks in each spatial direction
Type of test Continuous shock according to EN 60068-2-27/IEC 60068-2-27
Test result 10g for 16 ms, 1000 shocks in each spatial direction
Standards/regulations EN 61000-4-2
Contact discharge ± 6 kV (Test Level 3)
Indirect discharge ± 6 kV
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 3 GHz (Test Level 3)
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
Signal ± 1 kV (Data line, asymmetrical)
Standards/regulations EN 61000-6-4
EN 61000-4-6
Frequency range 0.15 MHz ... 80 MHz
Standards/regulations DIN EN 61643-21
Rated insulation voltage 85 V DC
IEC test classification C2
Conformance CE-compliant
ATEX  II 3 G Ex nA nC IIC T4 Gc X
UL, USA UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4
UL, USA/Canada Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4
Class I, Div. 2, Groups A, B, C, D
UL, Canada CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
Shipbuilding approval DNV GL
DNV GL-Temperature D
DNV GL-Humidity B
DNV GL-Vibration B
DNV GL-EMC B
Noxious gas test ISA-S71.04-1985 G3 Harsh Group A
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 6.0 19170100
eCl@ss 7.0 19170112
eCl@ss 8.0 19170112
eCl@ss 9.0 19170112
Back to top

ETIM

ETIM 5.0 EC002599
ETIM 6.0 EC002599
ETIM 7.0 EC002599
Back to top