Controller - ILC 171 ETH 2TX - 2700975

The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Back to top

Dimensions

Width 80 mm
Height 119.8 mm
Depth 71.5 mm
Back to top

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 55 °C
Ambient temperature (storage/transport) -25 °C ... 85 °C
Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Shock 25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation) 5g
Back to top

Control system

Engineering tool PC WORX
PC WORX EXPRESS
Programming languages supported Programming in acc. with IEC 61131-3
Diagnostics tool DIAG+
Configuration tool Config+ Version 1.01 or later
Back to top

IEC 61131 runtime system

Engineering tool PC WORX
PC WORX EXPRESS
Program memory 512 kByte
Mass storage 512 kByte
Retentive mass storage 48 kByte (NVRAM)
Number of control tasks 8
Realtime clock Yes
Back to top

Fieldbus function

Amount of process data max. 4096 Bit (INTERBUS)
max. 32768 Bit (internal Modbus /TCP client)
Number of supported devices max. 128
Number of local bus devices that can be connected max. 63 (observe current consumption)
Number of devices with parameter channel max. 24
Number of supported branch terminals with remote bus branch max. 3
Back to top

Data interfaces

Interface Ethernet 10Base-T/100Base-TX
Number 2
Connection method RJ45 socket
Transmission speed 10/100 Mbps
Interface INTERBUS local bus (master)
Number 1
Connection method Inline data jumper
Transmission speed 500 kBaud / 2 MBaud (can be switched)
Interface Parameterization/operation/diagnostics
Number 1
Connection method 6-pos. MINI DIN socket (PS/2)
Transmission speed max. 115.2 kbps
Back to top

PROFINET

Device function PROFINET device
Back to top

Direct I/Os

Input name Digital inputs
Number of inputs 8
Connection method Inline potential distributor
Connection technology 2, 3, 4-wire
Description of the input EN 61131-2 type 1 NPN/PNP
Output name Digital outputs
Number of outputs 4
Connection method Spring-cage connection
Connection technology 2, 3, 4-wire
Maximum output current per channel 500 mA
Back to top

Power supply

Typical current consumption 210 mA
Max. current consumption 870 mA (370 mA communications power + 500 mA analog voltage supply)
Supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC
Residual ripple ± 5 %
Power dissipation max. 5 W
Back to top

Mechanical design

Weight 295 g
Diagnostics display No
Controller redundancy No
Safety function No
Back to top

General data

Processor Altera Nios II 64 MHz
Back to top

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Interference emission Noise emission test as per EN 61000-6-4 EN 55011 Class A
Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symmetrical/asymmetrical), fieldbus cable shield 1 kV
Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, all interfaces 1 kVCriterion B, all interfaces 2 kV
Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Vibration (storage/transport) 5g
Shock 25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation) 5g
Back to top

Environmental Product Compliance

REACh SVHC 1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4
Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 4.0 27250203
eCl@ss 4.1 27240601
eCl@ss 5.0 27242215
eCl@ss 5.1 27242700
eCl@ss 6.0 27242200
eCl@ss 7.0 27242207
eCl@ss 8.0 27242207
eCl@ss 9.0 27242207
Back to top

ETIM

ETIM 3.0 EC000236
ETIM 4.0 EC000236
ETIM 5.0 EC000236
ETIM 6.0 EC000236
ETIM 7.0 EC000236
Back to top

UNSPSC

UNSPSC 6.01 43172015
UNSPSC 7.0901 43201404
UNSPSC 11 43172018
UNSPSC 12.01 43201404
UNSPSC 13.2 39122114