Controller - PLC-V8C/SC-24DC/BM2 - 2907447

PLC logic basic logic module, generation 2, with 16 I/Os, for plug-in connection to 8 digital or analog PLC-INTERFACE terminal blocks, can be extended to 48 I/Os, integrated realtime clock, micro USB socket, accommodates memory block and Bluetooth adapter, screw connection

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Connection diagram  

Connection diagram

Dimensional drawing  

Dimensional drawing
PLC logic with relay



Dimensional drawing  

Dimensional drawing
PLC logic with analogue terminals

Circuit diagram  

Circuit diagram
1 Field connection via COMBICON connector
2 PLC –V8C/
3 PLC-INTERFACE terminal blocks
4 Field connection via PLC-INTERFACE terminal blocks



Circuit diagram  

Circuit diagram

Circuit diagram  

Circuit diagram
Basic circuit diagram: inputs via PLC-INTERFACE with the example of one input terminal block with relay (230 V AC) and one input terminal block with solid-state relay (24 V DC).



Circuit diagram  

Circuit diagram
Basic circuit diagram: outputs via PLC-INTERFACE with the example of an output terminal block with relay, 1 PDT, and an output terminal block with solid-state relay.

Back to top

Dimensions

Width 50 mm
Height 44 mm
Depth 82.5 mm
Back to top

Ambient conditions

Ambient temperature (operation) -20 °C ... 50 °C
Ambient temperature (storage/transport) -20 °C ... 70 °C
Max. permissible relative humidity (operation) 95 %
Degree of protection IP20
Back to top

Power supply

Supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 26.4 V DC
Typical input current at UN 40 mA
Maximum input current at UN 160 mA
Protective circuit Reverse polarity protection
Surge protection
Status display Green LED
Back to top

Input data (digital)

Number of inputs 8 (2 configurable as analog)
Description of the input EN 61131-2, type 3
Input voltage 24 V DC
Signal level "0" signal < 5 V
Signal level "1" signal > 11 V
Input current "0" signal < 1 mA
Input current "1" signal typ. 2.5 mA
Status display Yellow LED
Back to top

Input data (analog)

Number of inputs 2 (IN6 and IN7 are configurable as analog)
Input voltage range 0 V ... 10 V
Input resistance > 3.5 kΩ
Back to top

Input data (PLC-INTERFACE)

Number of inputs ≤ 8
Description of the input technical data depends on the PLC-INTERFACE terminal block used
Input voltage 19 V DC
Typical current consumption 4 mA
Input resistance < 100 mΩ
Back to top

Output data

Number of outputs ≤ 8
Nominal output voltage 24 V DC
Nominal current 9 mA
Back to top

General

Realtime clock accuracy ±2 s/d
Realtime clock buffer time 96 h (Capacitor)
Color gray
Mounting position any
Assembly instructions can be plugged onto 8 x PLC-INTERFACE terminal blocks
Operating mode 100% operating factor
Degree of protection IP20
Back to top

Connection data

Connection name COMBICON connection
Connection method Screw connection
Stripping length 7 mm
Screw thread M2
Number of connections 1
Number of positions 10
Note Device supply and 8 x inputs
Conductor cross section solid 0.14 mm² ... 1.5 mm²
Conductor cross section flexible 0.14 mm² ... 1.5 mm²
0.25 mm² ... 0.5 mm² (Ferrule with plastic sleeve)
0.25 mm² ... 1.5 mm² (Ferrules without plastic sleeve)
Conductor cross section AWG 28 ... 16
Back to top

Connection data 2

Connection name Programming connection
Connection method Micro USB type B
Number of connections 1
Back to top

Connection data 3

Connection name INTERFACE system
Connection method Spring-cage connection
Stripping length 6 mm
Number of connections 1
Number of positions 3
Conductor cross section solid 0.14 mm² ... 0.5 mm²
Conductor cross section flexible 0.2 mm² ... 0.5 mm²
Conductor cross section AWG 26 ... 20
Back to top

Connection data 4

Connection name PLC logic - bus
Connection method Insulation displacement connection
Number of connections 1
Number of positions 4
Back to top

Connection data 5

Connection name Memory
Connection method S-PORT (socket)
Number of connections 1
Number of positions 12
Note For connecting the memory module
Back to top

Standards and Regulations

Designation Air clearances and creepage distances between the power circuits
Standards/regulations DIN EN 50178
Rated insulation voltage 50 V
Rated surge voltage 0.8 kV
Insulation Basic insulation
Pollution degree 2
Overvoltage category III
Conformance CE-compliant
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 27242216
eCl@ss 4.0 27250300
eCl@ss 4.1 27250300
eCl@ss 5.0 27242700
eCl@ss 5.1 27242700
eCl@ss 6.0 27242200
eCl@ss 7.0 27242216
eCl@ss 8.0 27242216
eCl@ss 9.0 27242216
Back to top

ETIM

ETIM 2.0 EC001417
ETIM 3.0 EC001417
ETIM 4.0 EC001417
ETIM 5.0 EC001417
ETIM 6.0 EC001417
ETIM 7.0 EC001417
Back to top

UNSPSC

UNSPSC 13.2 39122329
UNSPSC 18.0 39122329
UNSPSC 19.0 39122329
UNSPSC 20.0 39122329
UNSPSC 21.0 39122329
Back to top

Phoenix Contact UAB

Svitrigailos str. 11B
03228 Vilnius
+370 5 210 6321

  • Create PDF
  • Recommend
  • Feedback