Uninterruptible power supply - MINI-DC-UPS/12DC/4 - 2866598

Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Block diagram  

Block diagram

Diagram  

Diagram



Back to top

Dimensions

Width 67.5 mm
Height 99 mm
Depth 107 mm
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 30 mm / 30 mm
Back to top

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Max. permissible relative humidity (operation) 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Back to top

Input data

Nominal input voltage range 100 V AC ... 240 V AC
AC input voltage range 85 V AC ... 264 V AC
Input voltage range DC 100 V DC ... 350 V DC (UL508: 100...250 V DC)
Buffer time Can be set to: 0.5 min; 1 min; 2 min; 3 min; 5 min; 10 min; 15 min; 20 min; 30 min; permanent
Current consumption 0.65 A (230 V AC)
1.35 A (120 V AC)
Inrush current limiting/I²t < 1.1 A2s
Mains buffering time see diagram
Typical response time 100 ms
Power factor (cos phi) approx. 0.5
Protective circuit Varistor
Input fuse, integrated 3.15 A (slow-blow, internal)
Back to top

Output data

Nominal output voltage 12 V DC
Setting range of the output voltage (USet) 10 V DC ... 16 V DC (AC input voltage available, AC input voltage not available: Output voltage depending on the battery voltage: 13.6 V DC ... 9.6 V DC)
Nominal output current (IN) 4 A
Derating 60 °C ... 70 °C (2.5%/K)
Output current limit max. 7 A
Max. capacitive load unlimited
Control deviation < 1 % (change in load, static 10 % ... 90 %)
Power loss nominal load max. 10.5 W
Maximum power dissipation in no-load condition 3.8 W
Power dissipation battery operation 2.9 W
Efficiency > 82 %
Residual ripple < 50 mVPP
Peak switching voltages nominal load < 100 mVPP
Connection in parallel yes
Surge protection against internal surge voltages < 35 V DC
Feedback voltage resistance 35 V DC
Back to top

General

IQ technology no
Net weight 0.45 kg
Memory medium External, rechargeable battery 1.6 Ah / 2.6 Ah
Insulation voltage input/output 4 kV (type test)
2 kV (routine test)
Protection class II (in closed control cabinet)
MTBF (IEC 61709, SN 29500) > 728000 h (40 °C)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: horizontally 0 mm, vertically 50 mm
Back to top

Connection data, input

Connection method Pluggable COMBICON screw connections
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 8 mm
Screw thread M3
Back to top

Connection data, output

Connection method Pluggable COMBICON screw connections
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 8 mm
Screw thread M3
Back to top

Connection data for signaling

Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M3
Back to top

Standards

EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage EN 60950-1 (SELV)
EN 60204 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Rail applications EN 50121-4
Back to top

Conformance/approvals

UL approvals UL Listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Back to top

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge EN 61000-4-2
Electromagnetic HF field EN 61000-4-3
Fast transients (burst) EN 61000-4-4
Surge voltage load (surge) EN 61000-4-5
Conducted interference EN 61000-4-6
Voltage dips EN 61000-4-11
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 27040705
eCl@ss 4.0 27040600
eCl@ss 4.1 27040600
eCl@ss 5.0 27040600
eCl@ss 5.1 27040600
eCl@ss 6.0 27040600
eCl@ss 7.0 27040603
eCl@ss 8.0 27040603
eCl@ss 9.0 27040705
Back to top

ETIM

ETIM 2.0 EC000382
ETIM 3.0 EC000382
ETIM 4.0 EC000382
ETIM 5.0 EC000382
ETIM 6.0 EC000382
ETIM 7.0 EC000382
Back to top

UNSPSC

UNSPSC 6.01 30211510
UNSPSC 7.0901 39121011
UNSPSC 11 39121011
UNSPSC 12.01 39121011
UNSPSC 13.2 39121011
UNSPSC 18.0 39121011
UNSPSC 19.0 39121011
UNSPSC 20.0 39121011
UNSPSC 21.0 39121011
Back to top

PHOENIX CONTACT (I) Pvt. Ltd.

A-58/2, Okhla Industrial Area, Phase - II,
New Delhi-110 020
+91.11.30262800
  • Create PDF
  • Recommend
  • Feedback