Dimensional drawing |
![]() |
---|---|
Width | 40 mm |
Height | 30 mm |
Length | 190 mm |
Note on dimensions | Length without M12 flush-type connector |
Ambient temperature (operation) | 0 °C ... 50 °C |
---|---|
Ambient temperature (storage/transport) | -20 °C ... 75 °C |
Permissible humidity (operation) | 95 % |
Permissible humidity (storage/transport) | 95 % (non-condensing) |
Air pressure (operation) | 69 kPa ... 102 kPa |
Air pressure (storage/transport) | 69 kPa ... 102 kPa |
Degree of protection | IP67 |
Note | The PLD M-ME MC/D40 mounting holder (Order No. 2702491) or the PLD M-ME MB/D40 mounting bracket (Order No. 2702527) is required in order to mount the light. |
---|---|
Color | aluminum color |
Net weight | 399 g |
Mounting type | Screw mounting |
Assembly instructions | Mounting with mounting holders or mounting brackets, please observe the notes in the package slip. |
Mounting position | any |
Connection technology | M12 connector |
---|---|
Connection method | M12 connector, (A-coded) |
Number of positions | 4 |
Permissible conductor cross section | min. 0.34 mm² |
Supply voltage | 24 V DC |
Supply voltage range | 20 V DC ... 28 V DC |
Current consumption | typ. 0.21 A (at 24 V DC) |
Power consumption | approx. 5 W (at 24 V DC) |
Type of protection | Surge protection |
Reverse polarity protection |
Source of light type | LED |
---|---|
Number of LEDs | 12 |
Service life, lighting appliance | 60000 h (L70) |
Light color | Neutral white |
Color temperature / wavelength | 5000 K |
Color rendering index | 80 |
Luminous flux | approx. 480 lm (Net luminous flux) |
Illumination | max. 216 lx (Distance of 1 m) |
Average illumination | 156 lx (Distance of 1 m over 1 m² area) |
Emission angle | 85 ° (C0-C180) |
Immunity to ESD | Noise immunity test in accordance with EN 61547 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 4 kV contact discharge, 8 kV air discharge |
---|---|
Immunity to EF | Noise immunity test in accordance with EN 61547 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, field strength: 3 V/m |
Immunity to burst | Noise immunity test in accordance with EN 61547 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, ±0.5 kV |
Immunity to conducted interference | Noise immunity test in accordance with EN 61547 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, test voltage 3 V |
Interference emission | Noise emission test according to EN 61000-6-3 Radio interference properties EN 55015 Class B |
Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 4g |
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 50g | |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 years |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 10.0.1 | 27110345 |
---|---|
eCl@ss 11.0 | 27110345 |
eCl@ss 5.1 | 27119101 |
eCl@ss 7.0 | 27119010 |
eCl@ss 8.0 | 27119010 |
eCl@ss 9.0 | 27110345 |
ETIM 3.0 | EC000348 |
---|---|
ETIM 4.0 | EC000348 |
ETIM 5.0 | EC000348 |
ETIM 6.0 | EC000302 |
ETIM 7.0 | EC000302 |
UNSPSC 6.01 | 39111510 |
---|---|
UNSPSC 7.0901 | 39111510 |
UNSPSC 11 | 39111510 |
UNSPSC 12.01 | 39111510 |
UNSPSC 13.2 | 39101601 |
UNSPSC 18.0 | 39101601 |
UNSPSC 19.0 | 39101601 |
UNSPSC 20.0 | 39101601 |
UNSPSC 21.0 | 39101601 |
"$pageName" on