I/O module - AXL F DI16/1 DO16/1 2H - 2702106

Axioline F, Digital I/O module, Digital inputs: 16, 24 V DC, connection method: 1-wire, Digital outputs: 16, 24 V DC, 500 mA, connection method: 1-wire, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Connection diagram  

Connection diagram

Connection diagram  

Connection diagram
Connection with 1-wire technology



Diagram  

Diagram
Maximum outputs power consumption when inductive loads are switched off

Dimensional drawing  

Dimensional drawing



Back to top

Dimensions

Dimensional drawing
Width 35 mm
Height 129.9 mm
Depth 54 mm
Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
Back to top

Ambient conditions

Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection IP20
Back to top

Connection data

Designation Axioline F connector
Connection method Push-in connection
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm
Back to top

General

Mounting type DIN rail
Net weight 210 g
Note on weight specifications with connectors and bus base module
Back to top

Interfaces

Designation Axioline F local bus
No. of channels 2
Connection method Bus base module
Transmission speed 100 Mbps
Back to top

Axioline potentials

Designation Axioline F local bus supply (UBus)
Supply voltage 5 V DC (via bus base module)
Current consumption max. 120 mA (up to HW 01)
max. 60 mA (as of HW 02)
Power consumption max. 600 mW (up to HW 01)
max. 300 mW (as of HW 02)
Designation Supply for digital input and output modules (UIO)
Supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumption max. 8 A (provide external protection)
Power consumption max. 240 W (of which 1.25 W internal losses)
Type of protection Surge protection of the supply voltage
Polarity reversal protection of the supply voltage
Protection max. 8 A (polarity reversal protection up to 5 A)
Back to top

Digital inputs

Input name Digital inputs
Description of the input EN 61131-2 types 1 and 3
Connection method Push-in connection
Connection technology 1-wire
Number of inputs 16
Type of protection Polarity reversal protection of the inputs
Input filter time 3000 µs (default)
Input voltage range "0" signal -3 V DC ... 5 V DC
Input voltage range "1" signal 11 V DC ... 30 V DC
Nominal input current at UIN 2.4 mA
Back to top

Digital outputs

Output name Digital outputs
Connection method Push-in connection
Connection technology 1-wire
Number of outputs 16
Type of protection Short-circuit protection, overload protection of the outputs
Output voltage 24 V DC
Nominal output voltage 24 V DC
Maximum output current per channel 500 mA
Maximum output current per module 8 A (provide external protection)
Nominal load, inductive max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lamp max. 12 W (at nominal voltage)
Nominal load, ohmic max. 12 W (48 Ω, with nominal voltage)
Back to top

Electrical isolation

Test section 5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Back to top

Standards and Regulations

Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection class III, IEC 61140, EN 61140, VDE 0140-1
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 5.1 27242600
eCl@ss 6.0 27242600
eCl@ss 7.0 27242604
eCl@ss 8.0 27242604
eCl@ss 9.0 27242604
Back to top

ETIM

ETIM 5.0 EC001599
ETIM 6.0 EC001599
ETIM 7.0 EC001599
Back to top

UNSPSC

UNSPSC 13.2 32151602
Back to top

PHOENIX CONTACT (Ireland) Ltd

C6 The Exchange
Calmount Park
Ballymount
Dublin 12
D12 XE18
Ireland
(01)2051-300
  • Create PDF
  • Recommend
  • Feedback

This website uses cookies, by continuing to browse, you agree to our cookie policy. Read our privacy policy for more information.

Close