Distributed I/O device - AXL E PB DI8 DO8 M12 6M - 2701504

Axioline E, Digital I/O device, PROFIBUS DP, M12 fast connection technology, Digital inputs: 8, 24 V DC, connection method: 4-wire, Digital outputs: 8, 24 V DC, 500 mA, connection method: 3-wire, Metal housing, degree of protection: IP65/67

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Connection diagram  

Connection diagram

Dimensional drawing  

Dimensional drawing



Back to top

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
Back to top

Dimensions

Dimensional drawing
Width 60 mm
Height 185 mm
Depth 38 mm
Note on dimensions The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
Drill hole spacing 198.5 mm
Back to top

Ambient conditions

Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -25 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 %
Permissible humidity (storage/transport) 5 % ... 95 %
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protection IP65/IP67
Back to top

General

Housing material Zinc die-cast
Mounting type Wall mounting or DIN rail mounting; both with mounting plate.
Net weight 708.2 g
Back to top

Interfaces

Designation PROFIBUS DP
No. of channels 2
Connection method M12 fast connection technology
Note on the connection method B-coded
Designation connection point Copper cable
Transmission speed 9.6 kbps ... 12 Mbps (Automatic baud rate detection)
Transmission physics PROFIBUS-DP-compliant copper cable
Address area assignment 1 ... 126, adjustable
Number of positions 5
Back to top

System limits of the bus coupler

Designation PROFIBUS DP
Equipment type PROFIBUS slave
System-specific protocols PROFIBUS protocols DP V1
Back to top

Supply

Designation Module electronics and sensors (US)
Connection method M12 connector (T-coded)
Number of positions 4
Supply voltage 24 V DC
Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumption typ. 165 mA ±15 % (at 24 V DC)
Designation Actuators (UA)
Connection method M12 connector (T-coded)
Number of positions 4
Supply voltage 24 V DC
Supply voltage range 18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumption typ. 30 mA ±15 % (at 24 V DC)
Back to top

Digital inputs

Input name Digital inputs
Description of the input EN 61131-2 types 1 and 3
Connection method M12 connector, double occupancy
Connection technology 4-wire
Number of inputs 8
Type of protection Overload protection, short-circuit protection of sensor supply
Input filter time < 1000 µs
Input voltage range "0" signal 0 V ... 5 V DC
Input voltage range "1" signal 11 V DC ... 30 V DC
Nominal input current at UIN typ. 3 mA
Back to top

Digital outputs

Output name Digital outputs
Connection method M12 connector, double occupancy
Connection technology 3-wire
Number of outputs 8
Type of protection Overload protection, short-circuit protection of outputs
Output voltage 24 V DC
Nominal output voltage 24 V DC (from voltage UA)
Maximum output current per channel 500 mA
Nominal load, inductive 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, ohmic 12 W (48 Ω, with nominal voltage)
Back to top

Electrical isolation

Test section 24 V supply (communications power and sensor supply, digital inputs)/bus connection 500 V AC 50 Hz 1 min.
24 V supply (communications power and sensor supply, digital inputs)/FE 500 V AC 50 Hz 1 min.
Bus connection / FE 500 V AC 50 Hz 1 min.
24 V supply (actuator supply, digital outputs)/24 V supply (communications power and sensor supply, digital inputs) 500 V AC 50 Hz 1 min.
24 V supply (actuator supply, digital outputs)/bus connection 500 V AC 50 Hz 1 min.
24 V supply (actuator supply, digital outputs)/FE 500 V AC 50 Hz 1 min.
Back to top

Standards and Regulations

Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection class III, IEC 61140, EN 61140, VDE 0140-1
Back to top

Environmental Product Compliance

China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 4.0 27240404
eCl@ss 4.1 27240404
eCl@ss 5.0 27242204
eCl@ss 5.1 27242600
eCl@ss 6.0 27242600
eCl@ss 7.0 27242604
eCl@ss 8.0 27242604
eCl@ss 9.0 27242604
Back to top

ETIM

ETIM 2.0 EC001433
ETIM 3.0 EC001599
ETIM 4.0 EC001599
ETIM 5.0 EC001599
ETIM 6.0 EC001599
ETIM 7.0 EC001599
Back to top

UNSPSC

UNSPSC 6.01 43172015
UNSPSC 7.0901 43201404
UNSPSC 11 39121311
UNSPSC 12.01 39121311
UNSPSC 13.2 32151602
Back to top

PHOENIX CONTACT (Ireland) Ltd

C6 The Exchange
Calmount Park
Ballymount
Dublin 12
D12 XE18
Ireland
(01)2051-300
  • Create PDF
  • Recommend
  • Feedback

This website uses cookies, by continuing to browse, you agree to our cookie policy. Read our privacy policy for more information.

Close