Passive module - FLKM-2KS40/YCS/ZFKDS - 2314752

Universal interface module with 1:1 connection between the 40-pos. system connection and the spring-cage connection.

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Dimensional drawing  

Dimensional drawing

Circuit diagram  

Circuit diagram



Back to top

Note

Type of note Notes on operation
Note No additional touch protection is required when using a SELV/PELV voltage (≤ 25 V AC or 60 V DC).
Type of note Notes on operation
Note At least one functional insulation against adjacent modules is complied with (in the support rail direction). If the application has stricter requirements for the insulation (basic insulation or reinforced insulation), they must be realized by applying suitable measures (e. g. partition plates).
Back to top

Dimensions

Width 99.5 mm
Height 125.5 mm
Depth 60 mm
Back to top

Ambient conditions

Ambient temperature (operation) -20 °C ... 50 °C
Ambient temperature (storage/transport) -20 °C ... 70 °C
Maximum altitude ≤ 2000 m
Degree of protection IP00
≥ IP54 (Installation location)
Back to top

General

Max. permissible operating voltage 30 V DC
Nominal voltage UN 24 V DC ±10 %
Max. permissible current 100 mA (per path)
Number of positions 40
Mounting position any
Assembly instructions In rows with zero spacing
Back to top

Connection data

Connection name Field level
Connection method Spring-cage connection
Conductor cross section solid 0.2 mm² ... 4 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 12
Back to top

Connection data 2

Connection name Controller level
Connection method Yokogawa KS-compatible
Number of connections 1
Number of positions 40
Note Usable system cables: Phoenix Contact YUC40, Yokogawa KS1
Torque 0.5 Nm
Back to top

Supported controller

Controller YOKOGAWA CS3000 CentumVP
- suitable I/O card AAI543
AAI141
AAI143
AAI835
AAI841
AAI135
AAR181
AAT141
AAV141
AAV142
AAB841
AAV542
Controller YOKOGAWA STARDOM
- suitable I/O card NFAI141
NFAI43
NFAI543
NFAI135
NFAP135
NFAV141
NFAV142
NFAV542
NFAB841
NFAI841
NFAI835
Back to top

Standards and Regulations

Designation Air clearances and creepage distances
Standards/regulations DIN EN 50178
Rated insulation voltage 50 V
Rated surge voltage 0.5 kV
Insulation Functional insulation
Pollution degree 2
Overvoltage category II
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 27141152
eCl@ss 11.0 27141152
eCl@ss 4.0 27250300
eCl@ss 4.1 27250300
eCl@ss 5.0 27250300
eCl@ss 5.1 27250300
eCl@ss 6.0 27242600
eCl@ss 7.0 27141152
eCl@ss 8.0 27141152
eCl@ss 9.0 27141152
Back to top

ETIM

ETIM 5.0 EC002780
ETIM 6.0 EC002780
ETIM 7.0 EC002780
Back to top

UNSPSC

UNSPSC 6.01 30211824
UNSPSC 7.0901 39121421
UNSPSC 11 39121421
UNSPSC 12.01 39121421
UNSPSC 13.2 39121432
UNSPSC 18.0 39121432
UNSPSC 19.0 39121432
UNSPSC 20.0 39121432
UNSPSC 21.0 39121432
Back to top

PHOENIX CONTACT (Ireland) Ltd

C6 The Exchange
Calmount Park
Ballymount
Dublin 12
D12 XE18
Ireland
(01)2051-300
  • Create PDF
  • Recommend
  • Feedback