Connector - SACC-M12FSB-5PL SH - 1424664

Connector, Universal, 5-position, shielded, Socket straight M12, B-coded, Push-in connection, knurl material: Zinc die-cast, nickel-plated, external cable diameter 4 mm ... 8 mm

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Functional drawing  

Functional drawing
Slide the pressure nut and sleeve housing along the cable, strip the cable, shorten the shield, strip the single wires, connect the wires, in the case of a straight sleeve housing gently twist the wires together, stick the shielding foil around the shortened shield, in the case of a cable outside diameter < 6 mm stick an additional shielding foil around the wire pack, screw the sleeve housing to the plug insert, screw the pressure nut tight.

Dimensional drawing  

Dimensional drawing
Socket M12-SPEEDCON, straight, shielded



Schematic diagram  

Schematic diagram
Pin assignment M12 socket, 5-pos., B-coded, female side

Back to top

Dimensions

Diameter housing 19 mm
Length 59 mm
External cable diameter 4 mm ... 8 mm
Stripping length of the sheath 29 mm
Stripping length of the individual wire 7 mm
Back to top

Ambient conditions

Ambient temperature (operation) -40 °C ... 85 °C (Plug / socket)
Degree of protection IP65
IP67
Back to top

General

Note NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.
Rated current at 40°C 4 A (2 A when using 0.14 mm² conductors)
Rated voltage 48 V AC
60 V DC
Number of positions 5
Insulation resistance ≥ 100 MΩ
Coding B - inverse
Standards/regulations M12 connector IEC 61076-2-101
Shock, vibration EN 50155:2001
Signal type/category Universal
Status display No
Overvoltage category II
Degree of pollution 3
Connection method Push-in connection
Conductor cross section 0.14 mm² ... 0.75 mm² (without ferrule)
0.08 mm² ... 0.5 mm² (with ferrule)
0.14 mm² ... 0.75 mm² (solid)
Conductor cross section AWG 26 ... 18 (without ferrule)
28 ... 20 (with ferrule)
Insertion/withdrawal cycles ≥ 100
Torque 0.4 Nm (M12 knurl)
0.8 Nm (Connector with coupling sleeve)
3 Nm (Pressure nut with coupling sleeve)
Assembly instructions The wires can be connected both with ferrules and without ferrules
Back to top

Material

Flammability rating according to UL 94 V0
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Material of grip body Zinc die-cast, nickel-plated
Material, knurls Zinc die-cast, nickel-plated
Sealing material NBR
Additional material specifications TPE-U (Clamping cage, weight: 1.1 g)
PA 6 (Actuation lever)
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, R25, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
PA 6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Back to top

Standards and Regulations

Standard designation M12 connector
Standards/regulations IEC 61076-2-101
Standard designation Shock, vibration
Standards/regulations EN 50155:2001
Flammability rating according to UL 94 V0
Back to top

Environmental Product Compliance

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 5.1 27143423
eCl@ss 6.0 27279200
eCl@ss 7.0 27440104
eCl@ss 8.0 27440104
eCl@ss 9.0 27440102
Back to top

ETIM

ETIM 5.0 EC002635
ETIM 6.0 EC002635
ETIM 7.0 EC002635
Back to top

PHOENIX CONTACT (Ireland) Ltd

C6 The Exchange
Calmount Park
Ballymount
Dublin 12
D12 XE18
Ireland