Power cable - SAC-4P- 1,5-PUR/M12FRT SH - 1424116

Power cable, 4-position, PUR halogen-free, black RAL 9005, shielded (Advanced Shielding Technology), free cable end, on Socket angled M12, T-coded, cable length: 1.5 m

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Dimensional drawing  

Dimensional drawing
M12 x 1 socket, angled

Circuit diagram  

Circuit diagram
Contact assignment of the M12 socket



Schematic diagram  

Schematic diagram
Pin assignment of M12 socket, 4-pos., T-coded, socket side view

Cable cross section  

Cable cross section
PUR halogen-free black [PUR]



Back to top

Dimensions

Length of cable 1.5 m
Back to top

Ambient conditions

Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket)
Degree of protection IP65
IP67
Back to top

General

Rated current at 40°C 12 A
Rated voltage 63 V DC
Number of positions 4
Color handle area black
Insulation resistance ≥ 100 MΩ
Coding T power
Standards/regulations M12 connector IEC 61076-2-111
Status display No
Protective circuit/component unwired
Overvoltage category III
Degree of pollution 3
Insertion/withdrawal cycles > 100
Torque 0.4 Nm (M12 connector)
Back to top

Material

Flammability rating according to UL 94 V0
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA
Material of grip body PA
Material, knurls Zinc die-cast, nickel-plated
Back to top

Standards and Regulations

Standard designation M12 connector
Standards/regulations IEC 61076-2-111
Flammability rating according to UL 94 V0
Back to top

Cable

Cable type PUR halogen-free black
Cable type (abbreviation) PUR
Cable abbreviation LS9YC11Y-OB
Conductor cross section 4x 1.5 mm²
AWG power supply 16
Core diameter including insulation 2.4 mm
Thickness, insulation 1.2 mm (Outer cable sheath)
Wire colors brown, white, blue, black
Overall twist 4 wires optimally twisted
Shielding Tinned copper-braided shield, approx. 85% covering
External sheath, color black RAL 9005
External cable diameter D 9.7 mm ±0,3 mm
Smallest bending radius, fixed installation 49 mm
Smallest bending radius, movable installation 73 mm
Number of bending cycles 4000000
Bending radius 97 mm
Traversing path 10 m
Traversing rate 3 m/s
Acceleration 10 m/s²
Torsion force ± 25 °/m
Outer sheath, material PUR
Material conductor insulation PP
Conductor material Bare Cu litz wires
Insulation resistance ≥ 10 MΩ*km (at 20 °C)
Conductor resistance ≤ 13.3 Ω/km (at 20 °C)
Nominal voltage, cable 300 V AC
Test voltage, cable 1500 V AC (5 min.)
Flame resistance according to EN 60332-1-2
in acc. to UL 1581 VW1
Halogen-free according to VDE 0282-13 Appendix C
Resistance to oil in accordance with DIN EN 60811-2-1
According to DIN EN 50363-10-2
Ambient temperature (operation) -40 °C ... 90 °C (cable, fixed installation)
-30 °C ... 90 °C (cable, flexible installation)
Back to top

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 4.0 27140815
eCl@ss 4.1 27140815
eCl@ss 5.0 27143423
eCl@ss 5.1 27143400
eCl@ss 6.0 27279200
eCl@ss 7.0 27279218
eCl@ss 8.0 27279218
eCl@ss 9.0 27060311
Back to top

ETIM

ETIM 3.0 EC002061
ETIM 4.0 EC001855
ETIM 5.0 EC001855
ETIM 6.0 EC001855
ETIM 7.0 EC001855
Back to top

UNSPSC

UNSPSC 6.01 31251501
UNSPSC 7.0901 31251501
UNSPSC 11 31251501
UNSPSC 12.01 31251501
UNSPSC 13.2 31251501
Back to top

PHOENIX CONTACT (Ireland) Ltd

C6 The Exchange
Calmount Park
Ballymount
Dublin 12
D12 XE18
Ireland
(01)2051-300
  • Create PDF
  • Recommend
  • Feedback

This website uses cookies, by continuing to browse, you agree to our cookie policy. Read our privacy policy for more information.

Close