Ambient temperature (operation) | -40 °C ... 60 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Air pressure (operation) | 800 hPa ... 1080 hPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 660 hPa ... 1080 hPa (up to 3500 m above sea level) |
Degree of protection | IP65 |
IP66 | |
IP67 | |
IP68 | |
Note | Degree of protection when installed |
Designation | Wireless LAN |
---|---|
Antenna connection method | (Internal) |
Wireless standard | IEEE 802.11 |
a | |
b | |
g | |
n | |
Frequency band | 2.4 GHz |
5 GHz | |
Transmission power | max. 20 dBm (EIRP) |
Number of wireless interfaces | 1 IEEE 802. 11 a/b/g/n |
Wireless modules that can be connected | 60 (In access point mode) |
Operating modes | Access Point / Client Adapter / Repeater |
---|---|
Configuration | Web-based management, automated CLI |
Quality of service (QoS) | Yes |
Security | 802.11i |
WPA PSK (preshared key) | |
WPA2 | |
AES | |
TKIP | |
MAC filter | |
Supports 802.1X/RADIUS |
Number | 1 |
---|---|
Type | IEEE 802.11 a/b/g/n 2.4 GHz and 5 GHz to 300 Mbps |
Assembly instructions | Permanently installed |
Assembly instructions | Internal antenna |
---|---|
Number | 2 |
Connection method | permanently installed |
Note on the connection method | MIMO |
Gain | 5 dBi |
Interface | Ethernet (RJ45) |
---|---|
Number of interfaces | 1 |
Connection method | RJ45 |
Note on the connection method | Auto negotiation and autocrossing |
Transmission speed | 10/100 Mbps |
Transmission physics | Copper |
Transmission length | 100 m (per segment) |
Connection technology | COMBICON |
---|---|
Connection method | Push-in spring connection |
Designation | 1966101 FMC 1,5/ 3-STF-3,5 |
Number of positions | 3 |
Cross section range AWG | 24 ... 16 (Use copper wires rated 75° C (UL)) |
Note on the connection method | Recommended conductor cross section: 0.75 mm² |
Recommended ferrule: connection length 10 mm | |
Recommended crimping pliers: trapezoidal or square | |
Supply voltage | 24 V DC (SELV) |
Supply voltage range | 18 V DC ... 32 V DC (PELV/SELV) |
9 V DC ... 32 V DC (PELV/SELV (HW version 06 or later)) | |
Supply current | typ. 120 mA (at 24 V DC) |
Current consumption | max. 250 mA (at 18 V DC) |
max. 400 mA (at 9 V DC) |
Designation | 1966101 FMC 1,5/ 3-STF-3,5 |
---|---|
Connection method | Push-in spring connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 10 mm |
Housing material | Polycarbonate, PC |
---|---|
Material base plate | Die-cast zinc, nickel-plated |
Mounting type | Single-hole mounting |
Net weight | 370.2 g |
Degree of pollution | 2 |
Wireless licenses | USA, Canada |
Wireless licences | USA |
Canada | |
Note | Degree of protection when installed |
Standards/regulations | FCC/CFR 47, Part 15.107 |
---|---|
Test result | Class B |
Overvoltage category | none |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 years |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
eCl@ss 10.0.1 | 19170501 |
---|---|
eCl@ss 11.0 | 19170501 |
eCl@ss 4.0 | 24010504 |
eCl@ss 4.1 | 24010504 |
eCl@ss 5.0 | 19030100 |
eCl@ss 5.1 | 19030100 |
eCl@ss 6.0 | 19170200 |
eCl@ss 7.0 | 19170201 |
eCl@ss 8.0 | 19170201 |
eCl@ss 9.0 | 19170201 |
ETIM 3.0 | EC000817 |
---|---|
ETIM 4.0 | EC000816 |
ETIM 5.0 | EC000816 |
ETIM 6.0 | EC000816 |
ETIM 7.0 | EC000816 |
UNSPSC 6.01 | 43172710 |
---|---|
UNSPSC 7.0901 | 43223108 |
UNSPSC 11 | 43172710 |
UNSPSC 12.01 | 43223108 |
UNSPSC 13.2 | 43223108 |
UNSPSC 18.0 | 43223108 |
UNSPSC 19.0 | 43223108 |
UNSPSC 20.0 | 43223108 |
UNSPSC 21.0 | 43223108 |