Redundancy module - QUINT-ORING/24DC/2X40/1X80 - 2902879

Active QUINT redundancy module for DIN rail mounting with ACB (Auto Current Balancing) Technology and monitoring functions, input: 24 V DC/2x 40 A, output: 24 V DC/1 x 80 A, including mounted UTA 107/30 universal DIN rail adapter

Hinta:

Save money: Best price starts from {0} pieces!

Yleiskatsaus

Tekniset tiedot

Lisätarvikkeet

Hyväksynnät

Lataukset

Piirustukset



Block diagram  

Block diagram

Takaisin ylös

Dimensions

Width 66 mm
Height 130 mm
Depth 125 mm
Width with alternative assembly 122 mm
Height with alternative assembly 130 mm
Depth with alternative assembly 69 mm
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm
Takaisin ylös

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Installation height 2000 m
2000 m
Takaisin ylös

Input data

Nominal input voltage range 24 V DC
Input voltage range 18 V DC ... 28 V DC (SELV)
Nominal input current 2x 40 A (-25 °C ... 60 °C)
1x 80 A (-25 °C ... 60 °C)
Maximum input current 2x 45 A (-25°C ... 40°C)
1x 90 A (-25°C ... 40°C)
215 A (12 ms, SFB Technology)
Takaisin ylös

Output data

Nominal output voltage 0.2 V (< DC input)
24 V DC
Nominal output current (IN) 80 A (Increasing power)
40 A (Redundancy)
Derating 60 °C ... 70 °C (2.5%/K)
Connection in series No
Protection against overvoltage at the output (OVP) ≤ 32 V DC
Power loss nominal load max. 16 W (IOUT = 80 A)
Takaisin ylös

General

Net weight 0.9 kg
Efficiency > 98 %
MTBF (IEC 61709, SN 29500)
> 720000 h (40 °C)
Degree of protection IP20
Protection class III
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Takaisin ylös

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.5 mm²
Conductor cross section solid max. 16 mm²
Conductor cross section flexible min. 0.5 mm²
Conductor cross section flexible max. 16 mm²
Conductor cross section AWG min. 6
Stripping length 10 mm
Screw thread M4
Takaisin ylös

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.5 mm²
Conductor cross section solid max. 35 mm²
Conductor cross section flexible min. 0.5 mm²
Conductor cross section flexible max. 35 mm²
Conductor cross section AWG min. 2
Stripping length 18 mm
Screw thread M5
Takaisin ylös

Connection data for signaling

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 6 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 4 mm²
Conductor cross section AWG min. 16
Conductor cross section AWG max. 10
Stripping length 10 mm
Screw thread M3
Takaisin ylös

Standards

EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Takaisin ylös

Conformance/approvals

UL approvals UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Takaisin ylös

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge EN 61000-4-2
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 20 V/m (Test Level 3)
Frequency range 1 GHz ... 2 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 2 GHz ... 3 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 2 kV (Test Level 3 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Comments Criterion B
Surge voltage load (surge) EN 61000-4-5
Input 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Output 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion B
Conducted interference EN 61000-4-6
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Takaisin ylös

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Takaisin ylös

Luokitukset

ECLASS

ECLASS 10.0.1 27371010
ECLASS 11.0 27371010
ECLASS 4.0 27250300
ECLASS 4.1 27250300
ECLASS 5.0 27371000
ECLASS 5.1 27371000
ECLASS 6.0 27371000
ECLASS 7.0 27371010
ECLASS 9.0 27371010
Takaisin ylös

ETIM

ETIM 3.0 EC000599
ETIM 4.0 EC000599
ETIM 6.0 EC002540
ETIM 7.0 EC000683
Takaisin ylös

UNSPSC

UNSPSC 6.01 30211502
UNSPSC 7.0901 39121004
UNSPSC 11 39121004
UNSPSC 12.01 39121004
UNSPSC 13.2 39121004
UNSPSC 18.0 32151504
UNSPSC 19.0 32151504
UNSPSC 20.0 32151504
UNSPSC 21.0 32151504
Takaisin ylös

PHOENIX CONTACT OY

Niittytie 11
FI-01300 Vantaa
Contact Center:
+358 (0)9 3509 0290

Tekninen asiakaspalvelu:
+358 (0)9 3509 0260
  • Luo PDF
  • Suosittele edelleen
  • Palaute