Uninterruptible power supply - QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - 2320254

Uninterruptible energy supply with IQ technology and integrated energy storage for DIN rail mounting, input 24 V DC, output: 24 V DC/5 A, energy storage: lead AGM 1.3 Ah, incl. mounted UTA 107/30 universal DIN rail adapter

Hinta:

Save money: Best price starts from {0} pieces!

Yleiskatsaus

Tekniset tiedot

Lisätarvikkeet

Hyväksynnät

Lataukset

Piirustukset



Block diagram  

Block diagram

Pictogram  

Pictogram



Pictogram  

Pictogram

Takaisin ylös

Dimensions

Width 88 mm
Height 138 mm
Depth 125 mm
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm
Takaisin ylös

Ambient conditions

Degree of protection IP20
Ambient temperature (storage/transport) -20 °C ... 40 °C
Ambient temperature (charge) 0 °C ... 40 °C
Ambient temperature (discharge) -20 °C ... 50 °C
Max. permissible relative humidity (operation) ≤ 95 % (25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Takaisin ylös

Input data

Input voltage 24 V DC
Input voltage range 18 V DC ... 30 V DC
Current consumption (maximum) 9.3 A (24 V DC)
Current consumption (idle) 9.7 mA
Current consumption (charging process) 1.7 A
Fixed backup threshold ≤ 22.6 V DC
Takaisin ylös

Output data (24 V DC mains operation)

Nominal output voltage 24 V DC
Output voltage range (depends on the input voltage) 18 V DC ... 30 V DC (UOUT = UIN - 0,1 V DC)
Nominal output current (IN) 5 A (0 °C ... 40 °C)
POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB) 30 A (0 °C ... 40 °C)
Takaisin ylös

Output data (24 V DC battery operation)

Nominal output voltage 24 V DC
Output voltage range 19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
Nominal output current (IN) 5 A (0 °C ... 40 °C)
POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB) 32.5 A (0 °C ... 40 °C)
Takaisin ylös

General output data

Efficiency > 97.1 % (Mains operation, with charged energy storage)
Takaisin ylös

General

IQ technology Yes
Disposal Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations.
Net weight 2.2 kg
Memory medium VRLA-AGM Battery 1.2 Ah
Protection class III
MTBF (IEC 61709, SN 29500) > 806000 h (40 °C)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: horizontal 5 mm, vertical 50 mm
Takaisin ylös

Energy storage

Battery technology VRLA-AGM
Accumulator type 2x BB Battery BP1.2-12FR (from UPS V/C-level 05)
Buffer period 50 min. (1 A)
5 min. (5 A)
Takaisin ylös

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 20
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M4
Takaisin ylös

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 20
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M4
Takaisin ylös

Connection data for signaling

Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M4
Takaisin ylös

Standards

EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Rail applications EN 50121-4
Takaisin ylös

Conformance/approvals

UL approvals UL/C-UL Recognized UL 60950-1
UL Listed UL 508
Takaisin ylös

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge EN 61000-4-2
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 20 V/m
Frequency range 1 GHz ... 2 GHz
Test field strength 10 V/m
Frequency range 2 GHz ... 3 GHz
Test field strength 3 V/m
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 2 kV (Test Level 3 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Comments Criterion A
Surge voltage load (surge) EN 61000-4-5
Input 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Output 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion A
Conducted interference EN 61000-4-6
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Takaisin ylös

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 3
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Takaisin ylös

Luokitukset

ECLASS

ECLASS 10.0.1 27040705
ECLASS 11.0 27040705
ECLASS 4.0 27040600
ECLASS 4.1 27040600
ECLASS 5.0 27040600
ECLASS 5.1 27040600
ECLASS 6.0 27040600
ECLASS 7.0 27040603
ECLASS 9.0 27040705
Takaisin ylös

ETIM

ETIM 3.0 EC001039
ETIM 4.0 EC000382
ETIM 6.0 EC000382
ETIM 7.0 EC000382
Takaisin ylös

UNSPSC

UNSPSC 6.01 30211510
UNSPSC 7.0901 39121011
UNSPSC 11 39121011
UNSPSC 12.01 39121011
UNSPSC 13.2 39121011
UNSPSC 18.0 39121011
UNSPSC 19.0 39121011
UNSPSC 20.0 39121011
UNSPSC 21.0 39121011
Takaisin ylös

PHOENIX CONTACT OY

Niittytie 11
FI-01300 Vantaa
Contact Center:
+358 (0)9 3509 0290