Panel feed-through terminal block - HDFK 25-DP-PE - 0707798

The figure shows version HDFK 25 PE

Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 101 A, cross section: 6 mm² - 35 mm², connection direction of the conductor to plug-in direction: 0 °, width: 15.1 mm, color: green-yellow

Price:

Overview

Technical data

Accessories

Approvals

Downloads

Drawings



Dimensional drawing  

Dimensional drawing

Dimensional drawing  

Dimensional drawing



Back to top

Item properties

Brief article description PE panel panel feed-through terminal block
Range of articles HDFK 25
Pitch 15.1 mm
Number of positions 1
Number of connections 2
Back to top

Electrical parameters

Nominal current 101 A
Nom. voltage 500 V
Rated voltage (III/3) 500 V
Rated surge voltage (III/3) 6 kV
Back to top

Connection capacity, external

Connection method Screw connection with tension sleeve
Connection direction of the conductor to plug-in direction 0 °
Conductor cross section solid 6 mm² ... 35 mm²
Conductor cross section flexible 10 mm² ... 25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve 4 mm² ... 25 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve 4 mm² ... 25 mm²
2 conductors with same cross section, solid 2.5 mm² ... 10 mm²
2 conductors with same cross section, flexible 4 mm² ... 10 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 2.5 mm² ... 10 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 2.5 mm² ... 10 mm²
Internal cylindrical gage B8
Stripping length 19 mm
Torque 4 Nm ... 4.5 Nm
Back to top

Connection capacity, internal

Connection method Screw connection with tension sleeve
Connection direction of the conductor to plug-in direction 0 °
Conductor cross section solid 6 mm² ... 35 mm²
Conductor cross section flexible 10 mm² ... 25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve 4 mm² ... 25 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve 4 mm² ... 25 mm²
2 conductors with same cross section, solid 2.5 mm² ... 10 mm²
2 conductors with same cross section, flexible 4 mm² ... 10 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 2.5 mm² ... 10 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 2.5 mm² ... 10 mm²
Internal cylindrical gage B8
Stripping length 19 mm
Torque 4 Nm ... 4.5 Nm
Back to top

Material data - contact

Note WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Contact material Cu alloy
Surface characteristics tin-plated
Back to top

Material data - housing

Housing color green-yellow (6021 / 1018)
Insulating material PA
Insulating material group I
CTI according to IEC 60112 600
Flammability rating according to UL 94 V0
Glow wire flammability index GWFI according to EN 60695-2-12 850
Glow wire ignition temperature GWIT according to EN 60695-2-13 775
Temperature for the ball pressure test according to EN 60695-10-2 125 °C
Back to top

Dimensions for the product

Dimensional drawing
Caption Schematische Abbildung - weitere Details siehe Produktfamilienzeichnung im Download Center
Width [ w ] 15.1 mm
Pitch 15.1 mm
Back to top

Dimensions for mounting cutout

Plate thickness 5 mm ... 9.5 mm
Back to top

Packaging information

Type of packaging packed in cardboard
Pieces per package 50
Denomination packing units Pcs.
Back to top

Electrical tests

Rated current 101 A
Conductor cross section 25 mm²
Back to top

Air clearances and creepage distances

Clearances and creepage distances
Minimum clearance - inhomogeneous field (III/3) 5.5 mm
Minimum creepage distance value (III/3) 6.3 mm
Back to top

Standards and Regulations

Connection in acc. with standard CSA
IEC 60947-7-2
IEC / EN 
Flammability rating according to UL 94 V0
Safety note • Only electrically qualified personnel may install and operate the product.
To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering.
• Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data.
• The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection.
Back to top

Environmental Product Compliance

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 10.0.1 27141134
eCl@ss 11.0 27141134
eCl@ss 4.0 27141100
eCl@ss 4.1 27141100
eCl@ss 5.0 27141100
eCl@ss 5.1 27141100
eCl@ss 6.0 27141100
eCl@ss 7.0 27141134
eCl@ss 8.0 27141134
eCl@ss 9.0 27141134
Back to top

ETIM

ETIM 2.0 EC001283
ETIM 3.0 EC001283
ETIM 4.0 EC001283
ETIM 5.0 EC001283
ETIM 6.0 EC001283
ETIM 7.0 EC001283
Back to top

UNSPSC

UNSPSC 6.01 30211811
UNSPSC 7.0901 39121410
UNSPSC 11 39121410
UNSPSC 12.01 39121410
UNSPSC 13.2 39121410
UNSPSC 18.0 39121410
UNSPSC 19.0 39121410
UNSPSC 20.0 39121410
UNSPSC 21.0 39121410
Back to top

PHOENIX CONTACT Ltd

8240 Parkhill Drive
Milton, Ontario L9T 5V7
1-800-890-2820