Patch cable - NBC-R4AC/3,0-93K/R4AC - 1412376

Sercos III patch cable

Patch cable, degree of protection: IP20, number of positions: 4

Price:

Overview

Technical data

Approvals

Downloads

Drawings



Dimensional drawing  

Dimensional drawing
RJ45 connector, IP20

Circuit diagram  

Circuit diagram



Cable cross section  

Cable cross section
Sercos III [93K]

Back to top

Ambient conditions

Degree of protection IP20
Back to top

General data

Number of positions 4
Degree of pollution 1
Rated voltage (III/3) 72 V (DC)
Back to top

Characteristics head 1

Color black
Material (component) CuSn (Contact)
Ni/Au (Contact surface)
PA (Contact carriers)
PA (Housing)
Insertion/withdrawal cycles ≥ 750
Ambient temperature (operation) -25 °C ... 80 °C
Back to top

Characteristics head 2

Color black
Material (component) CuSn (Contact)
Ni/Au (Contact surface)
PA (Contact carriers)
PA (Housing)
Insertion/withdrawal cycles ≥ 750
Ambient temperature (operation) -25 °C ... 80 °C
Back to top

Standards and Regulations

Flammability rating according to UL 94 V0
Back to top

Cable

Cable type Sercos III
Cable type (abbreviation) 93K
UL AWM style 21694 (60°C / 600 V)
Signal type/category Sercos CAT5 (IEC 11801), 100 Mbps
Cable structure 1x4xAWG22/7; SF/TQ
Conductor cross section 4x 0.34 mm²
AWG signal line 22
Conductor structure signal line 7x 0.25 mm
Core diameter including insulation approx. 1.55 mm
Wire colors White, yellow, blue, orange
Type of pair shielding Aluminum-lined polyester foil
Overall twist Star quad
Shielding Tinned copper braided shield
External sheath, color signal red RAL 3020
Outer sheath thickness approx. 0.9 mm
External cable diameter D 6.5 mm ±0.2 mm
Minimum bending radius, fixed installation 3 x D
Minimum bending radius, flexible installation 7 x D
Cable weight 68 kg/km
Outer sheath, material PVC
Material, inner sheath PVC
Material conductor insulation PE
Conductor material Tin-plated Cu litz wires
Insulation resistance ≥ 0.5 GΩ*km
Conductor resistance ≤ 120 Ω/km
Wave impedance 100 Ω ±15 Ω (at 100 MHz)
Signal runtime 5.3 ns/m
Coupling resistance ≤ 20.00 mΩ/m (at 10 Hz)
Nominal voltage, cable 600 V
Test voltage Core/Core 2000 V (50 Hz, 1 min.)
Test voltage Core/Shield 2000 V (50 Hz, 1 min.)
Flame resistance according to UL 1685 (CSA FT 4)
Resistance to oil Resistant to oil to a limited extent
Other resistance UV resistant According to UL 1581, Section 1200
Ambient temperature (operation) -40 °C ... 70 °C (cable, fixed installation)
-40 °C ... 70 °C (cable, flexible installation)
Ambient temperature (installation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -50 °C ... 70 °C
Back to top

Environmental Product Compliance

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Back to top

Classifications

eCl@ss

eCl@ss 4.0 24010400
eCl@ss 4.1 24010400
eCl@ss 5.0 19030300
eCl@ss 5.1 19030300
eCl@ss 6.0 27061800
eCl@ss 7.0 27060308
eCl@ss 8.0 27060308
eCl@ss 9.0 27060308
Back to top

ETIM

ETIM 4.0 EC002498
ETIM 5.0 EC002599
ETIM 6.0 EC001262
ETIM 7.0 EC001262
Back to top

UNSPSC

UNSPSC 13.2 26121604
Back to top

PHOENIX CONTACT PTY Ltd

Unit 7, 2-8 South Street
Rydalmere NSW 2116

Fax: 1300 723 399
Customer Service Hotline
1300 786 411

  • Create PDF
  • Recommend
  • Feedback

This website uses cookies, by continuing to browse, you agree to our cookie policy. Read our privacy policy for more information.

Close