Panel feed-through terminal block - HDFK 10A GNYE 0709602

Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Screw connection with tension sleeve, number of positions: 1, load current: 57 A, cross section: 0.5 mm2 - 16 mm2, connection direction of the conductor to plug-in direction: 0 °, width: 10.1 mm, color: green-yellow


Product Details


External part, with current bar



Electrical properties
Rated surge voltage (III/2) 6 kV
Pollution degree 3
Rated voltage (III/3) 400 V
Air clearances and creepage distances | 4․ Insulation coordination
minimum clearance value - non-homogenous field (II/2) 8 mm
minimum creepage distance (III/3) 10 mm
minimum clearance value - non-homogenous field (III/3) 8 mm
Insulating material group I
minimum clearance value - non-homogenous field (III/2) 8 mm
minimum creepage distance (III/2) 8 mm
Comparative tracking index (IEC 60112:2003-01) CTI 600
minimum creepage distance (II/2) 8 mm
Rated surge voltage (II/2) 8 kV
Rated insulation voltage (III/3) 800 V
Rated insulation voltage (III/2) 1000 V
Specification IEC 60947-1:2007-06 + A1:2010-12
Rated insulation voltage (II/2) 1000 V
Rated surge voltage (III/3) 8 kV
Rated surge voltage (III/2) 8 kV
Application Plastic panel with DP-HDFK 10-5,5
Air clearances and creepage distances | 3․ Insulation coordination
minimum clearance value - non-homogenous field (II/2) 5.5 mm
minimum creepage distance (III/3) 6.3 mm
minimum clearance value - non-homogenous field (III/3) 5.5 mm
Insulating material group I
minimum clearance value - non-homogenous field (III/2) 5.5 mm
minimum creepage distance (III/2) 5.5 mm
Comparative tracking index (IEC 60112:2003-01) CTI 600
minimum creepage distance (II/2) 5.5 mm
Rated surge voltage (II/2) 6 kV
Rated insulation voltage (III/3) 500 V
Rated insulation voltage (III/2) 500 V
Specification IEC 60947-1:2007-06 + A1:2010-12
Rated insulation voltage (II/2) 1000 V
Rated surge voltage (III/3) 6 kV
Rated surge voltage (III/2) 6 kV
Application Plastic panel
Air clearances and creepage distances | 2․ Insulation coordination
minimum clearance value - non-homogenous field (II/2) 3 mm
minimum creepage distance (III/3) 3.2 mm
minimum clearance value - non-homogenous field (III/3) 3 mm
Insulating material group I
minimum clearance value - non-homogenous field (III/2) 3 mm
minimum creepage distance (III/2) 3 mm
Comparative tracking index (IEC 60112:2003-01) CTI 600
minimum creepage distance (II/2) 3 mm
Rated surge voltage (II/2) 4 kV
Rated insulation voltage (III/3) 250 V
Rated insulation voltage (III/2) 250 V
Specification IEC 60947-1:2007-06 + A1:2010-12
Rated insulation voltage (II/2) 500 V
Rated surge voltage (III/3) 4 kV
Rated surge voltage (III/2) 4 kV
Application Metal wall > 2.5 mm ... 4.0 mm
Air clearances and creepage distances | 1․ Insulation coordination
minimum clearance value - non-homogenous field (II/2) 5.5 mm
minimum creepage distance (III/3) 5.5 mm
minimum clearance value - non-homogenous field (III/3) 5.5 mm
Insulating material group I
minimum clearance value - non-homogenous field (III/2) 5.5 mm
minimum creepage distance (III/2) 5.5 mm
Comparative tracking index (IEC 60112:2003-01) CTI 600
minimum creepage distance (II/2) 5.5 mm
Rated surge voltage (II/2) 6 kV
Rated insulation voltage (III/3) 400 V
Rated insulation voltage (III/2) 500 V
Specification IEC 60947-1:2007-06 + A1:2010-12
Rated insulation voltage (II/2) 1000 V
Rated surge voltage (III/3) 6 kV
Rated surge voltage (III/2) 6 kV
Application Metal wall 1.0 mm ... 2.5 mm

Nominal current IN 57 A
57 A

Type of packaging packed in cardboard

Dimensional drawing
Pitch 10.1 mm
Width 10.1 mm
External dimensions
Length_external 18.1 mm
Height_external 28.5 mm
Internal dimensions
Height_inside 31 mm
Length_inside 24.5 mm

Note on application The technical data applies when using internal part HDFK 10I - 0707840
Safety note
Safety note • Only electrically qualified personnel may install and operate the product.
To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering.
• Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data.
• The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection.
 There is no electrical contact to the housing. Make sure that protective grounding is provided for green/yellow color variants and articles marked with PE.

Connection technology
Nominal cross section 10 mm2
Conductor connection exterior
2 conductors with same cross section, solid 0.5 mm2 ... 4 mm2
Torque 1.5 Nm ... 1.8 Nm
Conductor cross section flexible, with ferrule without plastic sleeve 0.5 mm2 ... 10 mm2
Internal cylindrical gage B6
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.5 mm2 ... 2.5 mm2
Conductor cross section solid 0.5 mm2 ... 16 mm2
Stripping length 10 mm
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm2 ... 6 mm2
Connection method Screw connection with tension sleeve
2 conductors with same cross section, flexible 0.5 mm2 ... 4 mm2
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.5 mm2 ... 10 mm2
Conductor cross section flexible 0.5 mm2 ... 10 mm2
Connection direction of the conductor to plug-in direction 0 °
Conductor connection interior
2 conductors with same cross section, solid 0.5 mm2 ... 4 mm2
Torque 1.5 Nm ... 1.8 Nm
Conductor cross section flexible, with ferrule without plastic sleeve 0.5 mm2 ... 10 mm2
Internal cylindrical gage B6
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.5 mm2 ... 2.5 mm2
Conductor cross section solid 0.5 mm2 ... 16 mm2
Stripping length 10 mm
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm2 ... 6 mm2
Connection method Screw connection with tension sleeve
2 conductors with same cross section, flexible 0.5 mm2 ... 4 mm2
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.5 mm2 ... 10 mm2
Conductor cross section flexible 0.5 mm2 ... 10 mm2
Connection direction of the conductor to plug-in direction 0 °

Material data - housing
Insulating material group I
Temperature for the ball pressure test according to EN 60695-10-2 125 °C
Glow wire flammability index GWFI according to EN 60695-2-12 850
CTI according to IEC 60112 600
Housing color green-yellow (6021 / 1018)
Insulating material PA
Flammability rating according to UL 94 V0
Glow wire ignition temperature GWIT according to EN 60695-2-13 775
Material data - contact
Contact material Cu alloy
Surface characteristics tin-plated
Note WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201

Number of positions 1


Order Key 0709602
Packing unit 50 pc
Minimum order quantity 50 pc
Note Made to Order (non-returnable)
GTIN 4017918242732
Weight per Piece (including packing) 12,4 GRM
Weight per Piece (excluding packing) 12,4 GRM
Customs tariff number 85369010
Country of origin GR



CSA

Approval Specification Data
Nominal voltage UN 300 V
Nominal current IN 65 A
AWG/kcmil 22-6
Min. cross section 22 mm²
Max. cross section 6 mm²

EAC

cULus Recognized

Approval Specification Data
Usegroup B C D
Nominal voltage UN 300 V 150 V 300 V
Nominal current IN 65 A 65 A 10 A
AWG/kcmil 22-6 22-6 22-6
Min. cross section 24 mm² 24 mm² 24 mm²
Max. cross section 6 mm² 6 mm² 6 mm²

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
China RoHS For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”


Compatible Products

Your advantages

Well-known connection principle allows worldwide use
Low temperature rise, thanks to maximum contact force
Tool-free snap-in principle enables easy mounting on the device panel
Automatic panel thickness compensation enables universal use