PLC-RSC-230AC/21-21/SO46/HI - Relay Module
1079387

PLC-INTERFACE consisting of PLC-BSC.../21-21/SO46/HI basic terminal block with screw connection and plug-in miniature relay with power contact, 2 changeover contacts, nominal input voltage of 230 V AC, with defined activation and deactivation thresholds


Product Details





Product type Relay Module
Product family PLC-INTERFACE
Application Filter to prevent interference
Operating mode 100% operating factor
Mechanical service life 3x 107 cycles
Insulation characteristics
Insulation Basic insulation
Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation Basic insulation
Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths
Overvoltage category III
Pollution degree 2

Maximum power dissipation for nominal condition 1.04 W
Test voltage (Winding/contact) 4 kV AC (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact) 2.5 kV AC (50 Hz, 1 min., changeover contact/changeover contact)
Air clearances and creepage distances between the power circuits
Rated surge voltage 4 kV

Coil side
Nominal input voltage UN 230 V AC
Input voltage range 190 V AC ... 264 V AC (20 °C)
Switch-on threshold 190 V AC
Switch-off threshold 170 V AC
Typical input current at UN 14 mA (50 Hz)
Input power dissipation for UN 3 VA
Typical response time 10 ms
Typical release time 8 ms
Coil voltage 110 V DC
Protective circuit Bridge rectifier
Input circuit RC element with threshold value switch
Operating voltage display Yellow LED

Switching
Contact type 2 changeover contacts
Type of switch contact Single contact
Drive and function monostable
Drive (polarity) bipolar
Contact material AgNi
Maximum switching voltage 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage 5 V AC/DC (10 mA)
Limiting continuous current 6 A
Maximum inrush current 15 A (300 ms)
Min. switching current 10 mA (5 V)
Interrupting rating (ohmic load) max. 140 W (at 24 V DC)
85 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
57 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity 2 A (at 24 V, DC13)
0.2 A (at 250 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 250 V, AC15)

Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14
Tightening torque 0.6 Nm ... 0.8 Nm

Width 14 mm
Height 80 mm
Depth 94 mm

Flammability rating according to UL 94 V0 (Housing)

Ambient conditions
Degree of protection Relay RT III (Relay)
IP20 (Relay base)
≥ IP54 (Installation location)
Ambient temperature (operation) -40 °C ... 50 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Altitude ≤ 2000 m

Corrosive gas test
Identification ISA-S71.04. G3 Harsh Group
EN 60068-2-60

Air clearances and creepage distances between the power circuits
Standards/regulations IEC 60947-5-1

Mounting type DIN rail mounting
Assembly instructions in rows with zero spacing
Mounting position any

Item number 1079387
Packing unit 1 pc
Minimum order quantity 10 pc
Sales Key C05
Product Key CK621C
Catalog Page Page 392 (C-5-2019)
GTIN 4055626798479
Weight per Piece (including packing) 73.84 g
Weight per Piece (excluding packing) 63.06 g
Customs tariff number 85364900
Country of origin DE


ECLASS

ECLASS-9.0 27371601
ECLASS-10.0.1 27371601
ECLASS-11.0 27371601
ECLASS-12.0 27371601
ECLASS-13.0 27371601

ETIM

ETIM 8.0 EC001437

UNSPSC

UNSPSC 21.0 39122300

cUL Recognized

Approval ID: FILE E 238705

UL Recognized

Approval ID: FILE E 238705

EAC

Approval ID: TR_TS_D_00573_c

DNV GL

Approval ID: TAE0000196
Approval Specification Data
Nominal Voltage UN Nominal Current IN Cross Section AWG Cross Section mm2

EAC

Approval ID: RU*C-DE.*08.B.00010

UL Listed

Approval ID: FILE E 172140

cUL Listed

Approval ID: FILE E 172140

cULus Recognized

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Compatible Products