TRIO-PS-2G/230AC-400DC/48DC/5
-
Power supply unit
1157806
Primary-switched TRIO power supply for DIN rail mounting, input: 230 V AC/400 V DC, output: 48 V DC / 5 A, dynamic boost, tool-free fast-connection technology for rigid and flexible conductors with ferrule
Product details
AC operation | |
Supply system configuration | Star network (TN, TT, IT (PE)) |
Nominal input voltage range | 220 V AC ... 240 V AC |
Input voltage range | 220 V AC ... 240 V AC -15 % ... +10 % |
Switch-on voltage | typ. 70 V AC |
Shut-down voltage | typ. 50 V AC |
Electric strength, max. | ≤ 300 V AC 15 s |
Typical national grid voltage | 230 V AC |
Voltage type of supply voltage | AC |
Inrush current integral (I2t) | < 0.3 A2s |
Inrush current limitation | < 13.5 A (after 1 ms) |
AC frequency range | 50 Hz ... 60 Hz ±10 % |
Mains buffering time | > 20 ms (190 V AC) |
> 20 ms (230 V AC) | |
Current consumption | 1.3 A (230 V AC) |
Nominal power consumption | 285.7 VA |
Power factor (cos phi) | 0.91 |
Input fuse | 3.15 A (internal (device protection)) |
Recommended breaker for input protection | 4 A ... 16 A (Characteristic B, C, Z) |
Discharge current to PE | < 3.5 mA |
< 1.7 mA (264 V AC, 60 Hz) | |
POWER factor | > 0.9 (230 V AC) |
DC operation | |
Nominal input voltage range | 220 V DC ... 400 V DC |
Input voltage range | 220 V DC ... 400 V DC -15 % ... +5 % |
Derating | < 99 V DC (2 %/V) |
Switch-on voltage | typ. 95 V DC |
Shut-down voltage | typ. 50 V DC |
Electric strength, max. | ≤ 420 V DC |
Voltage type of supply voltage | DC |
Mains buffering time | > 20 ms (185 V DC) |
> 25 ms (400 V DC) | |
Current consumption | 1.3 A (220 V DC) |
0.7 A (400 V DC) |
Efficiency | typ. 92.5 % (230 V AC) |
typ. 94 % (400 V DC) | |
Output characteristic | U/I with dynamic load reserve |
Nominal output voltage | 48.5 V DC ±1 % |
Nominal output current (IN) | 5 A |
Dynamic Boost (IDyn.Boost) | 7.5 A (5 s) |
Derating | > 60 °C ... 70 °C (2.5%/K) |
POWER factor | > 0.9 (120 V AC) |
> 0.9 (230 V AC) | |
Feedback voltage resistance | ≤ 60 V DC |
Protection against overvoltage at the output (OVP) | ≤ 58 V DC |
Control deviation | < 1.5 % (change in load, static 10 % ... 90 %) |
< 4 % (Dynamic load change 10 % ... 90 %, 10 Hz) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 20 mVPP (with nominal values) |
Short-circuit-proof | yes |
No-load proof | yes |
Output power | 240 W |
360 W | |
Peak switching voltages nominal load | < 15 mVPP |
Maximum no-load power dissipation | typ. 4 W (230 V AC) |
typ. 4 W (400 V DC) | |
Power loss nominal load max. | typ. 20 W (230 V AC) |
typ. 15 W (400 V DC) | |
Short-circuit current | < 7 A DC (Permanent) |
Rise time | 20 ms (UOUT (10 % ... 90 %)) |
Connection in parallel | yes, for redundancy and increased capacity |
Signal: DC OK | |
Continuous load current | 100 mA |
Signal relay 13/14 | |
Default | closed |
Digital | 30 V AC 30 V DC 100 mA |
Input | |
Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 4 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.25 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 1.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.25 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Output | |
Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 4 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.25 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 1.5 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.25 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Signal | |
Connection method | Push-in connection |
Conductor cross section, rigid min. | 0.2 mm² |
Conductor cross section, rigid max. | 0.75 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. | 0.75 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. | 0.2 mm² |
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. | 1 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 18 |
Types of signaling | Floating signal contact |
Signal output: LED status indicator | |
Signalization designation | DC OK |
Status display | LED |
Color | green |
DC OK | UOUT > 0.7 x UN (UN = 48 V DC) |
Number of phases | 1.00 |
Insulation voltage input/output | 3.5 kV AC (type test) |
1.5 kV AC (routine test) |
Product type | Power supply |
Product family | TRIO POWER |
MTBF (IEC 61709, SN 29500) | > 2220000 h (25 °C) |
> 1280000 h (40 °C) | |
> 560000 h (60 °C) | |
> 2220000 h (25 °C) | |
> 1280000 h (40 °C) | |
> 560000 h (60 °C) | |
Insulation characteristics | |
Protection class | I (in closed control cabinet) |
Degree of pollution | 2 |
Dimensional drawing |
|
Width | 42 mm |
Height | 130 mm |
Depth | 160 mm |
Installation dimensions | |
Installation distance right/left | 0 mm / 0 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Mounting type | DIN rail mounting |
Assembly instructions | alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
With protective coating | No |
Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
Housing material | Metal |
Type of housing | Aluminum (AlMg3) |
Hood version | Polycarbonate |
Ambient conditions | |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 70 °C (>60°C derating: 1.6%/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Ambient temperature (start-up type tested) | -40 °C |
Maximum altitude | ≤ 2000 m |
Climatic class | 3K3 (EN 60721) |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Shock | 20 m/s² (2g), 11 ms, ± 100 Schocks (DIN EN 50125-3, DIN EN 60068-2-27) |
Vibration (operation) | 5 Hz ... 2 kHz, 2.3 m/s² (0.23g) (RMS) 5 h (DIN EN 50125-3, DIN EN 60068-2-64) |
Rail applications | EN 50121-3-2 |
EN 50121-4 | |
EN 50124-1 | |
EN 50125-3 | |
IEC 62236-3-2 | |
IEC 62236-4 | |
IEC 62236-5 | |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Standard - Electrical safety | EN 61010-1 |
VDE 0805 (SELV) | |
Standard – Safety extra-low voltage | IEC 61010-1 (SELV) |
IEC 61010-2-201 (PELV) | |
Standard - Safe isolation | IEC 61010-2-201 |
IEC 61558-2-16 | |
Standard - Safety of power supply units up to 1100 V (insulation distances) | DIN EN 61558-2-16 |
Overvoltage category | |
EN 62477-1 | II (≤ 2000 m) |
III (≤ 2000 m) |
UL approvals | UL 61010-1 |
UL 61010-2-201 | |
Conformity/Approvals | |
SIL in accordance with IEC 61508 | 0 |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
Interference emission | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
EMC requirements for noise immunity | EN 61000-6-1 |
EN 61000-6-2 | |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Conducted noise emission | EN 55016 |
EN 61000-6-3 (Class B) | |
Noise emission | EN 55011 (EN 55022) |
Noise emission | EN 55016 |
EN 61000-6-3 (Class B) | |
Harmonic currents | |
Standards/regulations | EN 61000-3-2 |
Frequency range | Class A |
Flicker | |
Standards/regulations | EN 61000-3-3 |
Frequency range | 0 kHz ... 2 kHz |
Electrostatic discharge | |
Standards/regulations | EN 61000-4-2 |
Electrostatic discharge | |
Contact discharge | 6 kV (Test Level 4) |
Discharge in air | 8 kV (Test Level 4) |
Comments | Criterion A |
Electromagnetic HF field | |
Standards/regulations | EN 61000-4-3 |
Electromagnetic HF field | |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 20 V/m (Test Level 3) |
Frequency range | 1 GHz ... 2 GHz |
Test field strength | 10 V/m (Test Level X) |
Frequency range | 2 GHz ... 2.7 GHz |
Test field strength | 10 V/m (Test Level 3) |
Comments | Criterion A |
Fast transients (burst) | |
Standards/regulations | EN 61000-4-4 |
Fast transients (burst) | |
Input | 4 kV (Test Level 4 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 4 - asymmetrical) |
Comments | Criterion A |
Surge voltage load (surge) | |
Standards/regulations | EN 61000-4-5 |
Input | 2 kV (Test Level 4 - symmetrical) |
4 kV (Test Level 4 - asymmetrical) | |
Output | 1 kV (Test Level 3 - symmetrical) |
2 kV (Test Level 3 - asymmetrical) | |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Comments | Criterion A |
Conducted interference | |
Standards/regulations | EN 61000-4-6 |
Conducted interference | |
I/O/S | asymmetrical |
Frequency range | 0.15 MHz ... 80 MHz |
Comments | Criterion A |
Voltage | 10 V (Test Level 3) |
Voltage dips | |
Standards/regulations | EN 61000-4-11 |
Voltage | 230 V AC |
Frequency | 50 Hz |
Voltage dip | 70 % |
Number of periods | 25 periods |
Additional text | Test Level 2 |
Comments | Criterion A |
Voltage dip | 40 % |
Number of periods | 10 periods |
Additional text | Test Level 2 |
Comments | Criterion A |
Voltage dip | 0 % |
Number of periods | 1 period |
Additional text | Test Level 2 |
Comments | Criterion A |
Emitted interference | |
Standards/regulations | EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria | |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
Item number | 1157806 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Product key | CMPO14 |
GTIN | 4063151162887 |
Weight per piece (including packing) | 1,083.84 g |
Weight per piece (excluding packing) | 950 g |
Country of origin | CN |
ECLASS
ECLASS-11.0 | 27040701 |
ECLASS-12.0 | 27040701 |
ECLASS-13.0 | 27040701 |
ETIM
ETIM 9.0 | EC002540 |
REACh SVHC | Lead 7439-92-1 |