Vehicle charging inlet - CHARX T2HBI12-1AC32DC125-2,0M2
1270297

CHARX connect, Vehicle charging inlet, Locking actuator right, for charging with alternating current (AC) and with direct current (DC), for installation in electric vehicles (EV), Combined Charging System, CCS type 2, IEC 62196-2, IEC 62196-3, 125 A / 1000 V (DC), 32 A / 250 V (AC), length: 2 m, Front and rear mounting, M6, Generation 4, A protective cap is supplied as standard for the DC and AC contacts.


Product Details


Vehicle charging inlet for charging with direct current (DC), compatible with type 2 CCS vehicle charging connectors (EVSE), for installation in electric vehicles for electromobility (EV).



General A protective cap is supplied as standard for the DC and AC contacts.

Product type Vehicle charging inlet
Application for charging with alternating current (AC) and with direct current (DC)
for installation in electric vehicles (EV)
Combined Charging System
Type Locking actuator right
Locking type Locking in the inserted state with a locking mechanism
Insertion force < 100 N
Charging standard CCS type 2
Charging mode Mode 2, 3, 4

Number of phases 1
Type of signal transmission Pulse width modulation with modulated Powerline communication according to ISO/IEC 15118 / DIN SPEC 70121
Type of charging current DC, AC 1-phase
Note on the connection method Crimp connection, cannot be disconnected
Insulation resistance > 200 MΩ
Coding 4.7 kΩ (between PE and PP)
Maximum capacity 125 kW
Temperature measurement DC contacts: 2x PT1000 (DIN EN 60751)
Temperature monitoring AC contacts: PTC chain (DIN˽EN˽60738-1)
Power contact
Number 5 (L1, N, PE, DC+, DC-)
Rated voltage 250 V AC
1000 V DC
Rated current 32 A AC
125 A DC
Signal contact
Number 2 (CP, PP)
Rated voltage 30 V AC
Rated current 2 A
Temperature sensors
Sensor type PTC chain
Standards/regulations DIN˽EN 60738-1
Recommended measured current ≤ 1 mA (Umax= 16 V DC)
Tolerance at the sensor with the recommended measured current ±5 K
Temperature range -40 °C ... 130 °C
Locking actuator
Possible power supply range at the motor 9 V ... 16 V
Maximum voltage for locking detection 12 V
Typical motor current for locking 0.25 A
Reverse current of the motor max. 1.5 A
Max. dwell time with reverse current 1 s
Recommended adaptation time 600 ms
Pause time after entry or exit path 3 s
Service life insertion cycles > 10000 load cycles
Ambient temperature (operation) -40 °C ... 80 °C
Cable length 1 m
Cable structure 4 x 0.5 mm²
Lock recognition available
Mechanical emergency release available

Dimensional drawing
Width 108 mm
Height 140.25 mm
Depth 128.4 mm
Bore dimensions 117.65 mm x 90 mm, 117.65 mm x 83 mm

Color Housing black
Flammability rating according to UL 94 V0
Contact surface Ag
Material Plastic

Insertion/withdrawal cycles > 10000

Cable length 2 m (AC cables)
2 m (DC cables)
2 m (PE cable)
1 m (Locking actuator cables)
1 m (Temperature sensors cables)
1 m (Communications cables)
AC cable
Cable weight approx. 285 kg/km
Conductor structure 2 x 6 mm²
External cable diameter 12.6 mm ±0.2 mm
Outer sheath, material Silicone
External sheath, color orange
Conductor resistance ≤ 3.2 Ω/km
DC cable
Cable weight approx. 482 kg/km
Conductor structure 2 x 35 mm²
External cable diameter 14.1 mm ±0.3 mm
Outer sheath, material Silicone
External sheath, color orange
Conductor resistance ≤ 0.527 Ω/km
PE cable
Cable weight approx. 251 kg/km
Conductor structure 1 x 25 mm²
External cable diameter 8.6 mm ±0.1 mm
Outer sheath, material Silicone
External sheath, color green-yellow
Conductor resistance ≤ 0.743 Ω/km
Locking actuator cable
Cable weight 7 kg/km
Conductor structure 4 x 0.5 mm²
External cable diameter 1.6 mm -0.2 mm
Outer sheath, material PVC
Conductor resistance ≤ 37.1 Ω/km
Temperature sensor technology cable
Cable weight 7 kg/km
Conductor structure 5 x 0,5 mm²
External cable diameter 1.6 mm -0.2 mm
Outer sheath, material PVC
Conductor resistance ≤ 37.1 Ω/km
Ambient temperature (operation) -40 °C ... 130 °C
Communication cable
Cable weight 7 kg/km
Conductor structure 0.5 mm² + 0.5 mm²
External cable diameter 1.6 mm -0.2 mm
Outer sheath, material PVC
Conductor resistance ≤ 37.1 Ω/km
Cable structure
Single wire, cross section 6 mm²

Mechanical data
Insertion force < 100 N
Withdrawal force < 100 N
Design
Design Generation 4
Customer variations On request

Ambient conditions
Degree of protection IP55 (plugged in; when plugged in and ready to operate, the degree of protection is only ensued if both plug-in components are original products from Phoenix Contact or suitable standard-compliant products)
IP67 (Inner area of vehicle charging inlet)
Ambient temperature (operation) -40 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Altitude 4000 m (above sea level)

Standards
Standards/regulations IEC 62196-2
IEC 62196-3

Mounting type Front and rear mounting 0 to 90 degree frontal inclination possible Front and rear mounting 0 to 90 degree frontal inclination possible
Restrictions to mounting position Only 0 to 90 degree frontal inclination possible, see figure
Mounting hole diameter 6.80 mm (ø)
Fixing screws M6
Screws included in the scope of delivery none
Position of the locking actuator right-side

Item number 1270297
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key XWC
Product Key XWCAID
GTIN 4063151440213
Weight per Piece (including packing) 4,229 g
Weight per Piece (excluding packing) 4,229 g
Customs tariff number 85444290
Country of origin PL


ECLASS

ECLASS-9.0 27144706
ECLASS-11.0 27144706
ECLASS-10.0.1 27144706

ETIM

ETIM 8.0 EC002898

UNSPSC

UNSPSC 21.0

EAC

Approval ID: RU*DE*01.B.85589/21

REACh SVHC Lead 7439-92-1
Dechlorane Plus

Your advantages

Complete product range
Uniform, space-saving dimensions for the installation space and the screw connection points of all Phoenix Contact vehicle charging inlets
Developed and produced in accordance with the IATF 16949 automotive standard and ISO 9001
Safe against overheating with temperature measurement at every DC power contact
Integrated interlock during charging
Manual emergency release of the locking actuator
Protected and sealed against dirt and water with a high degree of protection