Power cable - SAC-5P-M12MSL FE/.../...
1276588

Power cable, 5-position, Variable cable type, Plug straight M12, coding: L, on free cable end, cable length: Free input (0.2 ... 40.0 m), for direct current up to 16 A/63 V


Product Details




Product type Power cable
Number of positions 5
Application Power supply
No. of cable outlets 1
Shielded no
Coding L - Power
Insulation characteristics
Overvoltage category III
Degree of pollution 3

Degree of protection IP65
IP67
Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket)

Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 63 V DC
Nominal current IN 12 A (1.5 mm²)
16 A (2.5 mm²)
Protective circuit unwired

Insertion/withdrawal cycles ≥ 100
Header 1
Head design Plug
Head cable outlet straight
Head thread type M12
Coding L
Head 2
Head design free cable end

Flammability rating according to UL 94 V0
Material of grip body PP
Contact material CuZn
Contact surface material Ni/Au
Contact carrier material PA
Cable gland material Zinc die-cast, nickel-plated

Cable length Free input (0.2 ... 40.0 m)
PUR halogen-free gray [280]
Dimensional drawing
Shielded no
UL AWM Style 20233 / 10493 (80°C/300 V)
Cable weight 185 kg/km
Cable type PUR halogen-free gray
Cable type (abbreviation) 280
External cable diameter 9.65 mm ±0.25 mm
Outer sheath, material PUR
External sheath, color gray RAL 7001
Thickness, outer sheath approx. 0.76 mm
Conductor material Bare Cu litz wires
Conductor structure, voltage supply 141x 0.15 mm
Conductor cross section 5x 2.5 mm²
AWG power supply 14
Material wire insulation PP
Thickness, insulation ≥ 0.31 mm
Wire diameter incl. insulation 2.85 mm ±0.1 mm
Single wire, color brown, white, blue, black, pink
Nominal voltage, cable ≤ 300 V AC
Test voltage, cable ≥ 3000 V AC (Spark test)
Conductor resistance ≤ 8 Ω/km (at 20 °C)
Cable insulation resistance ≥ 1 GΩ*km (at 20 °C)
Minimum bending radius, fixed installation 5 x D
Minimum bending radius, flexible installation 10 x D
Number of bending cycles 5000000
Minimum bending radius, drag chain applications 10 x D
Traversing path 10 m
Traversing rate 3 m/s
Acceleration 10 m/s²
Halogen-free in accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Resistance to oil according to DIN EN 60811-404, 168 h at 100 °C
Flame resistance According to UL 758/1581 (Cable Flame)
according to UL 758/1581 FT1
According to DIN EN 60332-1-2
Other resistance Hydrolysis and microbe resistant as per VDE 0282 section 10
Low adhesion
abrasion-resistant
Resistant to salt water
Ambient temperature (operation) -30 °C ... 80 °C (Cable, flexible installation)
-50 °C ... 80 °C (cable, fixed installation)
PUR halogen-free gray [290]
Dimensional drawing
Shielded no
UL AWM Style 20233 / 10493 (80°C/300 V)
Cable type PUR halogen-free gray
Cable type (abbreviation) 290
External cable diameter 9.1 mm ±0.25 mm
Outer sheath, material PUR
External sheath, color gray RAL 7001
Thickness, outer sheath approx. 1.3 mm
Conductor material Bare Cu litz wires
Conductor structure, voltage supply 78x 0.15 mm
Conductor cross section 5x 1.5 mm²
AWG power supply 16
Material wire insulation PP
Thickness, insulation ≥ 0.25 mm
Wire diameter incl. insulation 2.35 mm ±0.05 mm
Single wire, color brown, white, blue, black, pink
Nominal voltage, cable ≤ 300 V AC
Test voltage, cable ≥ 3000 V AC (Spark test)
Conductor resistance ≤ 13 Ω/km (at 20 °C)
Cable insulation resistance ≥ 1 GΩ*km (at 20 °C)
Minimum bending radius, fixed installation 5 x D
Minimum bending radius, flexible installation 10 x D
Number of bending cycles 5000000
Minimum bending radius, drag chain applications 10 x D
Traversing path 10 m
Traversing rate 3 m/s
Acceleration 10 m/s²
Halogen-free in accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
Resistance to oil according to DIN EN 60811-404, 168 h at 100 °C
Flame resistance According to UL 758/1581 (Cable Flame)
according to UL 758/1581 FT1
According to DIN EN 60332-1-2
Other resistance Hydrolysis and microbe resistant as per VDE 0282 section 10
Low adhesion
abrasion-resistant
Resistant to salt water
Ambient temperature (operation) -30 °C ... 80 °C (Cable, flexible installation)
-50 °C ... 80 °C (cable, fixed installation)
PVC gray [500]
Dimensional drawing
Shielded no
UL AWM Style 2464 (80°C/300 V)
Cable weight 205 kg/km
Cable type PVC gray
Cable type (abbreviation) 500
External cable diameter 10.1 mm ±0.3 mm
Outer sheath, material PVC
External sheath, color gray RAL 7001
Thickness, outer sheath approx. 0.76 mm
Conductor material Bare Cu litz wires
Conductor structure, voltage supply 141x 0.15 mm
Conductor cross section 5x 2.5 mm²
AWG power supply 14
Material wire insulation PVC
Thickness, insulation ≥ 0.36 mm
Wire diameter incl. insulation 3 mm ±0.1 mm
Single wire, color brown, white, blue, black, pink
Nominal voltage, cable ≤ 300 V AC
Test voltage, cable ≥ 3000 V AC (Spark test)
Conductor resistance ≤ 8 Ω/km (at 20 °C)
Cable insulation resistance ≥ 100 MΩ*km (at 20 °C)
Minimum bending radius, fixed installation 5 x D
Minimum bending radius, flexible installation 10 x D
Number of bending cycles 2000000
Minimum bending radius, drag chain applications 10 x D
Traversing path 10 m
Traversing rate 3 m/s
Acceleration 10 m/s²
Resistance to oil According to DIN EN 60811-404, 168 h at 60 °C
Flame resistance According to UL 758/1581 (Cable Flame)
according to UL 758/1581 FT1
According to DIN EN 60332-1-2
Ambient temperature (operation) -20 °C ... 80 °C (Cable, flexible installation)
-40 °C ... 80 °C (cable, fixed installation)
PVC gray [510]
Dimensional drawing
Shielded no
UL AWM Style 2464 (80°C/300 V)
Cable type PVC gray
Cable type (abbreviation) 510
External cable diameter 9.1 mm ±0.25 mm
Outer sheath, material PVC
External sheath, color gray RAL 7001
Thickness, outer sheath approx. 1.3 mm
Conductor material Bare Cu litz wires
Conductor structure, voltage supply 78x 0.15 mm
Conductor cross section 5x 1.5 mm²
AWG power supply 16
Material wire insulation PVC
Thickness, insulation ≥ 0.25 mm
Wire diameter incl. insulation 2.35 mm ±0.05 mm
Single wire, color brown, white, blue, black, pink
Nominal voltage, cable ≤ 300 V AC
Test voltage, cable ≥ 3000 V AC (Spark test)
Conductor resistance ≤ 13 Ω/km (at 20 °C)
Cable insulation resistance ≥ 1 GΩ*km (at 20 °C)
Minimum bending radius, fixed installation 5 x D
Minimum bending radius, flexible installation 10 x D
Number of bending cycles 2000000
Minimum bending radius, drag chain applications 10 x D
Traversing path 10 m
Traversing rate 3 m/s
Acceleration 10 m/s²
Resistance to oil According to DIN EN 60811-404, 168 h at 60 °C
Flame resistance According to UL 758/1581 (Cable Flame)
according to UL 758/1581 FT1
According to DIN EN 60332-1-2
Ambient temperature (operation) -20 °C ... 80 °C (Cable, flexible installation)
-40 °C ... 80 °C (cable, fixed installation)
Note This item is a power cable with a configurable cable type. The technical data for all possible cables is listed below.

Standards/specifications IEC 61076-2-111

Item number 1276588
Packing unit 1 pc
Minimum order quantity 1 pc
Sales Key BF1
Product Key BF1CDP
Customs tariff number 85444290
Country of origin PL


ECLASS

ECLASS-9.0 27060311
ECLASS-10.0.1 27060311
ECLASS-11.0 27060311

ETIM

ETIM 8.0 EC001855

UNSPSC

UNSPSC 21.0

UL Listed

Approval ID: E468743

cUL Listed

Approval ID: E468743

cULus Listed


REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads”

Your advantages

Easy and safe: 100% electrically tested plug-in components
Protection against mismatching, thanks to special L-coding