Device connector, front mounting - PV-FT-CCF-6-VPE250
1173570

Panel feed-through, Range of articles: Sunclix, Device connector, front mounting, number of positions: 1, min. conductor cross section: 6 mm2, Connection method: Crimp, Type of contact: Socket


Product Details




Safety note
Safety note • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that the protective or functional ground has been properly connected.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product.
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
• Operate the connector only when it is fully plugged in and interlocked.
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the minimum bending radius of the cable. Lay the cable without twisting it.

Product type Panel feed-through
Number of positions 1
Insertion force ≤ 20 N (uninstalled state)

Dimensional drawing
Width 8 mm
Height 7.7 mm
Length 31.1 mm

Maximum load current 40 A (for 6 mm²)
Rated voltage (III/2) 1500 V
Rated surge voltage (III/3) 16 kV
Contact resistance 0.45 mΩ
Contact resistance ≤ 0.45 mΩ (when plugged in)

Mechanical data
Insertion force ≤ 20 N (uninstalled state)
Withdrawal force ≤ 20 N (uninstalled state)

Flammability rating according to UL 94 V0
Contact surface Silver Ag
Contact material Cu
Contact surface material Ag

Insertion/withdrawal cycles 100

Cable structure
Single wire, cross section 6 mm²
Stripping length of the individual wire 8 mm +1 mm

Degree of protection (when plugged in) IP66 / IP68 (2 m / 24 h)
Degree of protection (not plugged in) IP20
Ambient temperature (operation) -40 °C ... 85 °C
Ambient temperature (assembly) -25 °C ... 50 °C

Item number 1173570
Packing unit 250 pc
Minimum order quantity 250 pc
Note Made to Order (non-returnable)
Product Key ABLBFA
GTIN 4063151199791
Weight per Piece (including packing) 2.406 g
Weight per Piece (excluding packing) 2.406 g
Customs tariff number 85366990
Country of origin DE


ECLASS

ECLASS-10.0.1 27440107
ECLASS-11.0 27440107

ETIM

ETIM 8.0 EC002635

UNSPSC

UNSPSC 21.0

EAC


China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values