You can integrate Axioline Smart Elements into systems with the Smart Element interface. This Smart Element is used to operate standard I/O devices with a serial interface on a bus system.
AXL SE RS485 EA
-
Communication module
1398499
Axioline Smart Elements, Communication module, interface RS-485: 1, Process data width: 20 bytes, Transparent protocol, Modbus/RTU (client support), Modbus/RTU (server support), degree of protection: IP20
This product needs further products for operation.
Mandatory accessories
Product details
Dimensional drawing |
|
Width | 14.9 mm |
Height | 62.2 mm |
Depth | 62 mm |
Smart Element interface | |
Number of interfaces | 1 |
Connection method | Card edge connector |
Transmission speed | See system in which you use the Smart Element. |
Start time until ready to operate | < 500 ms |
RS-485 | |
Number of interfaces | 1 |
Connection method | Push-in connection |
Note on the connection method | Use shielded cables. |
Transmission speed | 0 bps ... 230400 bps (can be parameterized) |
Transmission physics | Copper |
Termination resistor | 120 Ω (active, integrated) |
Data bits | 7 or 8 |
Stop bits | 1 or 2 |
Input buffer | 4 kByte |
Output buffer | 1 kByte |
Module | |
ID code (hex) | none |
Process data channel | 160 bit |
Input address area | 20 Byte |
Output address area | 20 Byte |
Product type | I/O component |
Product family | Axioline Smart Elements |
Type | modular |
Mounting position | See the system in which the Smart Element is used. |
Special properties | Process data width: 20 bytes |
Transparent protocol | |
Modbus/RTU (client support) | |
Modbus/RTU (server support) | |
Insulation characteristics | |
Overvoltage category | II (IEC 60664-1, EN 60664-1) |
Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
Maximum power dissipation for nominal condition | 0.35 W |
Potentials: Communications power supply of the Smart Elements (USE) | |
Supply voltage | using card edge connectors |
Potentials: I/O supply (UP) | |
Supply voltage | 24 V DC (using card edge connectors) |
Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
Current draw | max. 12 mA |
Current consumption | min. 8 mA (without connected peripherals) |
Power consumption | max. 270 mW |
min. 220 mW | |
Protective circuit | Surge protection; See the system in which the Smart Element is used. |
Reverse polarity protection; Polarity protection diode | |
Electrical isolation/isolation of the voltage ranges | |
Test voltage: Communications supply / 24 V supply (I/O) | 500 V AC, 50 Hz, 1 min |
Test voltage: Logic supply / RS-485 interface | 500 V AC, 50 Hz, 1 min |
Test voltage: Communications supply / functional ground | 500 V AC, 50 Hz, 1 min |
Test voltage: 24 V supply (I/O) / RS-485 interface | 2.5 kV |
Test voltage: 24 V supply (I/O) / functional ground | 2.5 kV |
Test voltage: RS-485 interface / functional ground | 2.5 kV |
Connection technology | |
Connection name | I/O |
Note on the connection method | Please observe the information provided on conductor cross-sections in the “Axioline Smart Elements” user manual. |
Conductor connection | |
Connection method | Push-in connection |
Conductor cross-section rigid | 0.25 mm² ... 1.5 mm² |
Conductor cross-section flexible | 0.25 mm² ... 1.5 mm² |
Conductor cross-section AWG | 24 ... 16 |
Conductor cross-section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross-section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Stripping length | 8 mm |
I/O | |
Connection method | Push-in connection |
Note on the connection method | Please observe the information provided on conductor cross-sections in the “Axioline Smart Elements” user manual. |
Conductor cross-section, rigid | 0.25 mm² ... 1.5 mm² |
Conductor cross-section, flexible | 0.25 mm² ... 1.5 mm² |
Conductor cross-section AWG | 24 ... 16 |
Conductor cross-section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² |
Conductor cross-section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² |
Stripping length | 8 mm |
Ambient conditions | |
Ambient temperature (operation) | -40 °C ... 70 °C |
Degree of protection | IP20 |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Mounting type | Plug-in mounting (Smart Element slot) |
Mounting position | See the system in which the Smart Element is used. |
Item number | 1398499 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | DRMBAE |
Product key | DRMBAE |
GTIN | 4063151976736 |
Weight per piece (including packing) | 36.8 g |
Weight per piece (excluding packing) | 36 g |
Country of origin | DE |
ECLASS
ECLASS-13.0 | 27242608 |
ECLASS-15.0 | 27242608 |
EU RoHS | |
Fulfills EU RoHS substance requirements | Yes |
Exemption | 7(a), 7(c)-I |
China RoHS | |
Environment friendly use period (EFUP) |
EFUP-50
An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
|
EU REACH SVHC | |
REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
Compatible products
-
SZS 0,4X2,5 VDE - Screwdriver 1205037
-
CRIMPFOX 6 - Crimping pliers 1212034
-
CRIMPFOX DUO 10 - Crimping pliers 1031721
-
CRIMPFOX 10T-F - Crimping pliers 1134913
-
MM-TML (EX4,2)R C1 TR/BK - Label 0803979
-
SK 5,0 WH:REEL - Marker strip 0805221
-
UM6M-TM (5X12) - Marker for terminal blocks 0830928
-
UCT6M-TM 5 - Marker for terminal blocks 0830756
Your advantages
One serial input and output channel in RS-485 format
Modbus/RTU client and server support
Transmission speed can be set up to 230,400 bps
Number of data bits, stop bits and parity can be set
Ambient temperature during operation from -40°C ... 70°C
Satisfies environmental and EMC conditions in accordance with IEC 61850-3
Device rating plate stored
PHOENIX CONTACT AS
Strømsveien 344; N-1081 Oslo