Data cable preassembled - SAC-5P- 5,0-923/MINFS DN 1418439

Bus system cable, DeviceNet™, 5-position, PUR halogen-free, silver-gray RAL 7001, shielded, free cable end, on Socket straight 7/8"-16UNF, cable length: 5 m


Product Details




Outer sheath, material PUR
External sheath, color silver-gray RAL 7001
Single wire, color Red-black, blue-white
Cable structure 2xAWG24/19+2xAWG22/19
UL AWM Style 21198 (80°C/300 V)
21198 (80°C/300 V)
Cable length 5 m
Cable weight 90 kg/km
Flame resistance UL 1581, Sec. 1060 (FT-1)
Cable type CANopen®/DeviceNet™, PUR, gray 923
Shielded yes
Nominal voltage, cable ≤ 300 V (Peak value, not for high-power applications)
Conductor cross section 0.25 mm2
Conductor structure signal line 19x 0.13 mm
AWG signal line 24
Electrical properties
Wave impedance 120 Ω ±10 % (with 1 MHz)
Test voltage Core/Shield 2000 V (50 Hz, 1 min.)
Nominal voltage, cable ≤ 300 V (Peak value, not for high-power applications)
Loop resistance ≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Cable insulation resistance ≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Cable capacity nom. 40 nF/km (Data cable)
Test voltage Core/Core 2000 V (50 Hz, 1 min.)
Cable structure
External sheath, color silver-gray RAL 7001
gray RAL 7001
Outer sheath, material PUR
PUR
Conductor structure, voltage supply 19x 0.15 mm
External cable diameter 6.7 mm ±0.3 mm
Type of pair shielding Plastic-coated aluminum foil, aluminum side outside
Single wire, color Red-black, blue-white
Wire diameter incl. insulation 1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
Cable structure 2xAWG24/19+2xAWG22/19
Twisted pairs 2 cores to the pair
Optical shield covering 80 %
AWG power supply 22
Shielding Tinned copper braided shield
Cable type CANopen®/DeviceNet™, PUR, gray
CANopen®/DeviceNet™, PUR, gray
Signal type/category CANopen®
DeviceNet™
DeviceNet™
Conductor structure signal line 19x 0.13 mm
Overall twist 2 pairs around a drain wire in the center to the core
AWG signal line 24
Material wire insulation Foamed PE (Data cable)
PE (Power supply)
Cable type (abbreviation) 923
Conductor material Tin-plated Cu litz wires
Mechanical properties
Minimum bending radius, drag chain applications 10 x D
Minimum bending radius, fixed installation 5 x D
Number of bending cycles 5000000
Bending radius 70 mm
Traversing rate 3 m/s
Acceleration 3 m/s2
Traversing path 4.5 m
Minimum bending radius, flexible installation 10 x D
Attenuation
Damping ≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Ambient conditions
Ambient temperature (operation) -20 °C ... 80 °C (cable, flexible installation)
-40 °C ... 80 °C (cable, fixed installation)
Halogen-free in accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Flame resistance UL 1581, Sec. 1060 (FT-1)
IEC 60332-1
Other resistance Low adhesion
Pin assignment
Contact | Color (signal designation) | Contact (optional) 1 (Socket) | SR (shield)
2 (Socket) | RD (V+)
3 (Socket) | BK (V-)
4 (Socket) | WH (CAN_H)
5 (Socket) | BU (CAN_L)

Head 2
Type Socket, straight
Header 1
Type free cable end

Transmission medium Copper
Nominal current IN 5.2 A
Contact resistance < 5 mΩ
Nominal voltage UN 300 V AC
300 V DC

Status display present No
Status display No

Contact material CuZn
Color Handle area black
Material of grip body TPU
Cable gland material Stainless steel
Contact surface material Au
Sealing material TPU
Flammability rating according to UL 94 HB
Contact carrier material PA 6.6

Signal type/category DeviceNet™
Bus system DeviceNet™

Ambient temperature (operation) -40 °C ... 80 °C (Plug / socket)
Degree of protection IP65
IP67
IP65/IP67

Number of positions 5
Coding A - standard
Application Standard
Insulation characteristics
Overvoltage category II
Degree of pollution 3


Order Key 1418439
Packing unit 1 pc
Minimum order quantity 1 pc
Note Made to Order (non-returnable)
Catalog Page Page 418 (C-4-2015)
GTIN 4046356538299
Weight per Piece (including packing) 331.4 GRM
Weight per Piece (excluding packing) 331.4 GRM
Customs tariff number 85444290
Country of origin DE



China RoHS Environmentally Friendly Use Period = 50 years
China RoHS For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”