Circular connectors (device side) - SACC-EC-M12FS-5CON-PG 9/1,5 VA 1425196

Sensor/actuator flush-type socket, 5-pos., M12, A-coded, front/screw mounting with Pg9 thread, can be positioned, with 0.5 m TPE litz wire, 5 x 0.34 mm2, stainless steel version

Product Details




Mounting type Front wall/screw mounting, can be positioned

Cable length 1.5
Shielded no
Electrical properties
Nominal voltage, cable 300 V
Test voltage, cable 2000 V AC
Conductor resistance ≤ 57.6 Ω/km
Cable insulation resistance ≥ 20 MΩ*km
Cable structure
Cable type TPE litz wire
Signal type/category Universal
Conductor material Tin-plated Cu litz wires
Conductor structure signal line 7x 0.25 mm
AWG signal line 22
Material wire insulation TPE
Thickness, insulation 0.21 mm
Wire diameter incl. insulation 1.2 mm ±0.07 mm
Single wire, color Black, brown,blue, white, gray
Ambient conditions
Ambient temperature (operation) -25 °C ... 85 °C (cable, flexible installation)
Ambient temperature (operation) -40 °C ... 85 °C (cable, fixed installation)

Header 1
Type Flush-type socket, straight

Rated surge voltage 1.5 kV AC
Contact resistance ≤ 3 mΩ
Insulation resistance > 100 MΩ
Nominal voltage UN 60 V
Nominal current IN 4 A

Degree of protection IP65/IP67/IP69/IP69K
Degree of protection IP67
Degree of protection IP69K
Degree of protection IP65/IP67/IP69K
Ambient temperature (operation) -25 ... -85 (Plug / socket)
Ambient temperature (operation) -25 °C ... 90 °C (cable, fixed installation)
Ambient temperature (operation) -25 °C ... 85 °C (cable, flexible installation)
Ambient temperature (operation) -40 °C ... 85 °C (cable, fixed installation)

Connection technology
Connection method Individual wires
Conductor connection
Connection method Individual wires

Notes on operation The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Environmental Product Compliance
China RoHS Environmentally friendly use period: unlimited = EFUP-e
China RoHS No hazardous substances above threshold values
Safety note
Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
Safety note • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
Safety note • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
Safety note • The products are suitable for applications in plant, controller, and electrical device engineering.
Safety note • When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
Safety note • Assembled products may not be manipulated or improperly opened.
Safety note • Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
Safety note • When using the product in direct connection with third-party manufacturers, the user is responsible.
Safety note • For operating voltages > 50 V AC, conductive connector housings must be grounded
Safety note • Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
Safety note • Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
Safety note • Only use tools recommended by Phoenix Contact
Safety note • Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
Safety note • Ensure that the protective or functional ground has been properly connected.
Safety note • VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
Safety note • The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

Standards/specifications according to IEC 61076-2-101

Flammability rating according to UL 94 V0
Sealing material FKM
Contact material CuZn
Contact surface material Au
Contact carrier material PA66 GF
Cable gland material Stainless steel

Number of positions 5
Coding A-coded
Insulation characteristics
Overvoltage category II
Degree of pollution 3


Order Key 1425196
Packing unit 1 pc
Minimum order quantity 50 pc
Note Made to Order (non-returnable)
GTIN 4055626387116
Weight per Piece (including packing) 51.2 GRM
Weight per Piece (excluding packing) 47.1 GRM
Customs tariff number 85444290
Country of origin DE



UL Recognized

Approval Specification Data
Nominal voltage UN 60 V
Nominal current IN 4 A
AWG/kcmil 22
Max. cross section 22 mm²

cULus Recognized

Approval Specification Data
Nominal voltage UN 60 V
Nominal current IN 4 A
AWG/kcmil 22
Min. cross section 22 mm²
Max. cross section 20 mm²

EAC


Your advantages

Pre-assembled with litz wires for immediate use
Customer-specific assemblies and litz wire lengths available
Sealed on the litz wire side for optimum leak-tightness
All standard pin assignments and codings for signal, data, and power transmission with a uniform design-in design
For high transmission safety: shield connection to the housing with optional EMC nut