VS-M12FSEC-OE-93E-LI/0,5
   - 
  Device connector front mounting
    
      1136432
      
      
    
  
      Device connector front mounting, Ethernet CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, PUR, water blue RAL 5021, shielded, Socket, straight, M12-SPEEDCON, D-coding, on free cable end, Bus line, cable length: 0.5 m, Ethernet flexible CAT5, 2-pair, this item is expected to be lead-free from Q1 2027 in accordance with RoHS II without exception 6c (Pb < 0.1%), a lead-free alternative is possible on request in advance
Product details
| Notes on operation | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. | 
| Order information: | Lock nut is included in the scope of delivery | 
| General | Contact connection method: Crimp connection | 
| Product type | Data cable preassembled | 
| Application | Data | 
| Sensor type | Ethernet | 
| Number of positions | 4 | 
| No. of cable outlets | 1 | 
| Shielded | yes | 
| Coding | D | 
| Thread type | M12 | 
| Insulation characteristics | |
| Overvoltage category | II | 
| Degree of pollution | 3 | 
| Bus system | Ethernet | 
| Signal type/category | Ethernet CAT5 (IEC 11801:2002), 100 Mbps | 
| Ethernet CAT5 (IEC 11801), 100 Mbps | 
| Contact resistance | ≤ 3 mΩ | 
| Insulation resistance | ≥ 100 MΩ | 
| Nominal voltage UN | 48 V AC | 
| 60 V DC | |
| Nominal current IN | 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed) | 
| Transmission medium | Copper | 
| Transmission speed | 100 Mbps | 
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) | 
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 100 | 
| Flammability rating according to UL 94 | V0 | 
| Seal material | NBR | 
| Contact material | CuZn | 
| Contact surface material | Au | 
| Contact carrier material | PA 6.6 | 
| Material for screw connection | Zinc die-cast, nickel-plated | 
| Outer sheath, material | PUR | 
| Contact carrier color | turquoise | 
| Connection technology | |
| Connection method | Bus line | 
| Conductor connection | |
| Contact connection type | Socket | 
| Connection method | Bus line | 
| Tightening torque | 2 Nm ... 3 Nm (Installation-side) | 
| Connection 1 | |
| Head design | Socket | 
| Head cable outlet | straight | 
| Head thread type | M12 | 
| Head locking type | SPEEDCON | 
| Coding | D | 
| Connection 2 | |
| Head design | free cable end | 
| Cable length | 0.5 m | 
| Ethernet flexible CAT5, 2-pair [93E] | |
| Dimensional drawing |  | 
| UL AWM Style | 21238 (80 °C / 600 V) | 
| Number of positions | 4 | 
| Shielded | yes | 
| Cable type | Ethernet flexible CAT5, 2-pair [93E] | 
| Conductor structure | 2x2xAWG26/7, SF/UTP | 
| AWG signal line | 26 | 
| Conductor cross section | 2x 2x 0.14 mm² | 
| Wire diameter incl. insulation | 0.95 mm ±0.05 mm | 
| External cable diameter | 6.40 mm ±0.2 mm | 
| Outer sheath, material | PUR | 
| External sheath, color | water blue RAL 5021 | 
| Conductor material | Bare Cu litz wires | 
| Material wire insulation | Foamed PE | 
| Single wire, color | white/orange-orange, white/green-green | 
| Twisted pairs | 2 cores to the pair | 
| Overall twist | Two pairs with two fillers to the core | 
| Optical shield covering | 70 % | 
| Insulation resistance | ≥ 5 GΩ*km | 
| Loop resistance | ≤ 280.00 Ω/km | 
| Wave impedance | 100 Ω ±5 Ω (at 100 MHz) | 
| Nominal voltage, cable | ≤ 100 V | 
| Test voltage Core/Core | 2000 V (50 Hz, 1 min.) | 
| Test voltage Core/Shield | 2000.00 V (50 Hz, 1 min.) | 
| Minimum bending radius, fixed installation | 4 x D | 
| Minimum bending radius, flexible installation | 8 x D | 
| Smallest bending radius, fixed installation | 26 mm | 
| Smallest bending radius, movable installation | 51 mm | 
| Halogen-free | according to IEC 60754-1 | 
| Flame resistance | according to IEC 60332-1-2 | 
| in accordance with UN ECE-R 118.03 | |
| UL 1581, Section 1060 and UL 2556, Section 9.3 (FT1) | |
| UL 1581, Section 1100 and UL 2556, Section 9.1 (HFT/FT2) | |
| Resistance to oil | in accordance with IEC 60811-404 | 
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) | 
| -30 °C ... 70 °C (Cable, flexible installation) | |
| Ambient conditions | |
| Degree of protection | IP65 | 
| IP67 | |
| IP65/IP67 | |
| Ambient temperature (operation) (male connector/female connector) | -25 °C ... 85 °C (Plug / socket) | 
| -40 °C ... 85 °C (without mechanical actuation) | |
| UL Type Rating | Type 4 (indoor use only) | 
| Standard designation | M12 circular connector | 
| Standards/specifications | according to IEC 61076-2-101 | 
| Item number | 1136432 | 
| Packing unit | 1 pc | 
| Minimum order quantity | 50 pc | 
| Note | Made to order (non-returnable) | 
| Sales key | ABQDEI | 
| Product key | ABQDEI | 
| GTIN | 4063151072421 | 
| Weight per piece (including packing) | 43.72 g | 
| Weight per piece (excluding packing) | 43.703 g | 
| Customs tariff number | 85444200 | 
| Country of origin | DE | 
ECLASS
| ECLASS-13.0 | 27440103 | 
| ECLASS-15.0 | 27440103 | 
ETIM
| ETIM 9.0 | EC003570 | 
UNSPSC
| UNSPSC 21.0 | 39121400 | 
| EU RoHS | |
| Fulfills EU RoHS substance requirements | Yes | 
| Exemption | 6(c) | 
| China RoHS | |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. | 
| EU REACH SVHC | |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) | 
| SCIP | 005a3522-c631-4bc4-b02d-4a543f387e6b | 
Compatible products
Your advantages
Preassembled with cables in various standard lengths for immediate use
        Customer-specific assemblies and cable lengths can be supplied
        Sealed on the cable side for optimum tightness of seal
        Cable designs for all common networks and fieldbuses
        For high transmission safety: shield connection to the housing with optional EMC nut
        PHOENIX CONTACT AG
        
        Zürcherstrasse 22, CH-8317 Tagelswangen